English
Language : 

XC3S50A-4FTG256C Datasheet, PDF (13/132 Pages) Xilinx, Inc – Architectural and Configuration Overview
DC and Switching Characteristics
General Recommended Operating Conditions
Table 8: General Recommended Operating Conditions
Symbol
Description
Min
Nominal
Max
Units
Commercial
TJ
Junction temperature
Industrial
0
–
85
°C
–40
–
100
°C
VCCINT
VCCO (1)
VCCAUX
VIN
TIN
Internal supply voltage
Output driver supply voltage
Auxiliary supply voltage(2)
VCCAUX = 2.5
VCCAUX = 3.3
PCI IOSTANDARD
Input voltage(3)
All other
IP or IO_#
IOSTANDARDs IO_Lxxy_#(4)
Input signal transition time(5)
1.14
1.10
2.25
3.00
–0.5
–0.5
–0.5
–
1.20
1.26
V
–
3.60
V
2.50
2.75
V
3.30
3.60
V
–
VCCO+0.5
V
–
4.10
V
–
4.10
V
–
500
ns
Notes:
1. This VCCO range spans the lowest and highest operating voltages for all supported I/O standards. Table 11 lists the recommended VCCO
range specific to each of the single-ended I/O standards, and Table 13 lists that specific to the differential standards.
2. Define VCCAUX selection using CONFIG VCCAUX constraint.
3. See XAPP459, “Eliminating I/O Coupling Effects when Interfacing Large-Swing Single-Ended Signals to User I/O Pins.”
4. For single-ended signals that are placed on a differential-capable I/O, VIN of –0.2V to –0.5V is supported but can cause increased leakage
between the two pins. See Parasitic Leakage in UG331, Spartan-3 Generation FPGA User Guide.
5. Measured between 10% and 90% VCCO. Follow Signal Integrity recommendations.
DS529-3 (v2.0) August 19, 2010
www.xilinx.com
13