Analog-to-Digital Converter (ADC)
■ Trigger configuration
Most of the ADC control logic runs at the ADC clock rate of 14-18 MHz. The internal ADC divider
is configured automatically by hardware when the system XTAL is selected. The automatic clock
divider configuration targets 16.667 MHz operation for all Stellaris devices.
11.3.2.1
Interrupts
The register configurations of the sample sequencers dictate which events generate raw interrupts,
but do not have control over whether the interrupt is actually sent to the interrupt controller. The
ADC module's interrupt signals are controlled by the state of the MASK bits in the ADC Interrupt
Mask (ADCIM) register. Interrupt status can be viewed at two locations: the ADC Raw Interrupt
Status (ADCRIS) register, which shows the raw status of the various interrupt signals, and the ADC
Interrupt Status and Clear (ADCISC) register, which shows active interrupts that are enabled by
the ADCIM register. Sequencer interrupts are cleared by writing a 1 to the corresponding IN bit in
ADCISC.
11.3.2.2
Prioritization
When sampling events (triggers) happen concurrently, they are prioritized for processing by the
values in the ADC Sample Sequencer Priority (ADCSSPRI) register. Valid priority values are in
the range of 0-3, with 0 being the highest priority and 3 being the lowest. Multiple active sample
sequencer units with the same priority do not provide consistent results, so software must ensure
that all active sample sequencer units have a unique priority value.
11.3.2.3
Sampling Events
Sample triggering for each sample sequencer is defined in the ADC Event Multiplexer Select
(ADCEMUX) register. The external peripheral triggering sources vary by Stellaris family member,
but all devices share the "Controller" and "Always" triggers. Software can initiate sampling by setting
the SSx bits in the ADC Processor Sample Sequence Initiate (ADCPSSI) register.
Care must be taken when using the "Always" trigger. If a sequence's priority is too high, it is possible
to starve other lower priority sequences.
11.3.3
Hardware Sample Averaging Circuit
Higher precision results can be generated using the hardware averaging circuit, however, the
improved results are at the cost of throughput. Up to 64 samples can be accumulated and averaged
to form a single data entry in the sequencer FIFO. Throughput is decreased proportionally to the
number of samples in the averaging calculation. For example, if the averaging circuit is configured
to average 16 samples, the throughput is decreased by a factor of 16.
By default the averaging circuit is off and all data from the converter passes through to the sequencer
FIFO. The averaging hardware is controlled by the ADC Sample Averaging Control (ADCSAC)
register (see page 413). There is a single averaging circuit and all input channels receive the same
amount of averaging whether they are single-ended or differential.
11.3.4
Analog-to-Digital Converter
The converter itself generates a 10-bit output value for selected analog input. Special analog pads
are used to minimize the distortion on the input. An internal 3 V reference is used by the converter
resulting in sample values ranging from 0x000 at 0 V input to 0x3FF at 3 V input when in single-ended
input mode.
394
July 15, 2014
Texas Instruments-Production Data