English
Language : 

DS90UB926Q-Q1 Datasheet, PDF (10/57 Pages) Texas Instruments – 5- to 85-MHz 24-Bit Color FPD-Link III Deserializer With Bidirectional Control Channel
DS90UB926Q-Q1
SNLS422B – JULY 2012 – REVISED JANUARY 2015
www.ti.com
6.7 DC and AC Serial Control Bus Characteristics
Over 3.3-V supply and temperature ranges unless otherwise specified.(1) (2) (3)
PARAMETER
TEST CONDITIONS
MIN TYP MAX UNIT
VIH
VIL
VHY
VOL
Iin
tR
tF
tSU;DAT
tHD;DAT
tSP
Cin
Input High Level
Input Low Level Voltage
Input Hysteresis
SDA RiseTime – READ
SDA Fall Time – READ
Set Up Time — READ
Hold Up Time — READ
Input Filter
Input Capacitance
SDA and SCL
SDA and SCL
SDA, IOL = 1.25mA
SDA or SCL, Vin = VDD33 or GND
SDA, RPU = 10kΩ, Cb ≤ 400pF (Figure 9)
See Figure 9
See Figure 9
SDA or SCL
0.7 ×
VDD33
GND
0
–10
VDD33 V
0.3 ×
VDD33
V
>50
mV
0.36 V
+10 µA
430
ns
20
ns
560
ns
615
ns
50
ns
<5
pF
(1) The Electrical Characteristics tables list ensured specifications under the listed Recommended Operating Conditions except as
otherwise modified or specified by the Electrical Characteristics Conditions and/or Notes. Typical specifications are estimations only and
are not ensured.
(2) Typical values represent most likely parametric norms at VDD = 3.3 V, TA = 25°C, and at the Recommended Operation Conditions at the
time of product characterization and are not ensured.
(3) Current into device pins is defined as positive. Current out of a device pin is defined as negative. Voltages are referenced to ground
except VOD and ΔVOD, which are differential voltages.
6.8 Timing Requirements
tR
tF
tSU;DAT
tHD;DAT
tSP
SDA RiseTime – READ
SDA Fall Time – READ
Set Up Time — READ
Hold Up Time — READ
Input Filter
SDA, RPU = 10kΩ, Cb ≤
400pF (Figure 9)
See Figure 9
See Figure 9
MIN
NOM
MAX UNIT
430
ns
20
ns
560
ns
615
ns
50
ns
10
Submit Documentation Feedback
Copyright © 2012–2015, Texas Instruments Incorporated
Product Folder Links: DS90UB926Q-Q1