Addr
(Hex)
0x06
0x07
0x08
0x09
0x0A
0x0B
0x0C
Name
DES ID
DESAlias
SlaveID
SlaveAlias
CRC Errors
CRC Errors
General Status
Table 1. DS90UB913Q Control Registers (continued)
Bits Field
R/W
7:1
Desializer Device
ID
RW
0 Freeze Device ID RW
7:1
Deserializer ALIAS
ID
RW
0 RSVD
7:1 SLAVE ID
RW
0 RSVD
7:1 SLAVE ALIAS ID RW
0 RSVD
7:0 CRC Error Byte 0
R
7:0 CRC Error Byte 1
R
7:5 Rev-ID
R
4 RX Lock Detect
R
3
BIST CRC Error
Status
R
2 PCLK Detect
R
1 DES Error
R
0 LINK Detect
R
Default
0x00
0
0
0x00
0x00
0
0
0
0
0
0
0
0
Description
7-bit Deserializer Device ID Configures the I2C Slave ID
of the remote Deserializer. A value of 0 in this field
disables I2C access to the remote Deserializer. This field
is automatically configured by the Bidirectional Control
Channel once RX Lock has been detected. Software may
overwrite this value, but should also assert the FREEZE
DEVICE ID bit to prevent overwriting by the Bidirectional
Control Channel.
1: Prevents auto-loading of the Deserializer Device ID by
the bidirectional control channel. The ID will be frozen at
the value written.
0: Update
7-bit Remote Deserializer Device Alias ID Configures the
decoder for detecting transactions designated for an I2C
Deserializer device. The transaction will be remapped to
the address specified in the DES ID register.
A value of 0 in this field disables access to the remote
I2C Slave.
Reserved
7-bit Remote Slave Device ID Configures the physical I2C
address of the remote I2C Slave device attached to the
remote Deserializer. If an I2C transaction is addressed to
the Slave Alias ID, the transaction will be remapped to
this address before passing the transaction across the
Bidirectional Control Channel to the Deserializer. A value
of 0 in this field disables access to the remote I2C slave.
Reserved
7-bit Remote Slave Device Alias ID Configures the
decoder for detecting transactions designated for an I2C
Slave device attached to the remote Deserializer. The
transaction will be remapped to the address specified in
the Slave ID register. A value of 0 in this field disables
access to the remote I2C Slave.
Reserved
Number of back-channel CRC errors during normal
operation
Least Significant byte
Number of back-channel CRC errors during normal
operation
Most Significant byte
Revision ID
0x00: Production
1: RX LOCKED
0: RX not LOCKED
1: CRC errors in BIST mode
0: No CRC errors in BIST mode
1: Valid PCLK detected
0: Valid PCLK not detected
1: CRC error is detected during communication with
Deserializer.
This bit is cleared upon loss of link or assertion of CRC
ERROR RESET in register 0x04.
0: No effect
1: Cable link detected
0: Cable link not detected
This includes any of the following faults
— Cable Open
— '+' and '-' shorted
— Short to GND
— Short to battery