Three Port 10/100 Managed Ethernet Switch with MII
Datasheet
CSR Read
Idle
CSR Read Auto
Increment /
Decrement
Idle
Write
Command
Register
Read
Command
Register
CSR_BUSY = 1
CSR_BUSY = 0
Read Data
Register
Write
Command
Register
Read
Command
Register
CSR_BUSY = 1
CSR_BUSY = 0
last No
data?
Read Data
Register
Yes
Write
Command
Register
Read Data
Register
Figure 6.2 Switch Fabric CSR Read Access Flow Diagram
6.2.3
Flow Control Enable Logic
Each switch fabric port (0,1,2) is provided with two flow control enable inputs per port, one for
transmission and one for reception. Flow control on transmission allows the transmitter to generate
back pressure in half-duplex mode, and pause packets in full-duplex. Flow control in reception enables
the reception of pause packets to pause transmissions.
The state of these enables is based on the state of the ports duplex and Auto-negotiation settings and
the values of the corresponding Manual Flow Control register (Port 1 Manual Flow Control Register
(MANUAL_FC_1), Port 2 Manual Flow Control Register (MANUAL_FC_2), or Port 0(External MII)
Manual Flow Control Register (MANUAL_FC_MII)). Table 6.1 details the switch fabric flow control
enable logic.
When in half-duplex mode, the transmit flow control (back pressure) enable is determined directly by
the BP_EN_x bit of the ports manual flow control register. When Auto-negotiation is disabled, or the
MANUAL_FC_x bit of the ports manual flow control register is set, the switch port flow control enables
during full-duplex are determined by the TX_FC_x and RX_FC_x bits of the ports manual flow control
Revision 1.2 (04-08-08)