English
Language : 

LAN9313 Datasheet, PDF (394/398 Pages) SMSC Corporation – Three Port 10/100 Managed Ethernet Switch with MII
14.6
Three Port 10/100 Managed Ethernet Switch with MII
Datasheet
Clock Circuit
The LAN9313/LAN9313i can accept either a 25MHz crystal (preferred) or a 25MHz single-ended clock
oscillator (+/- 50ppm) input. If the single-ended clock oscillator method is implemented, XO should be
left unconnected and XI should be driven with a nominal 0-3.3V clock signal. The input clock duty cycle
is 40% minimum, 50% typical and 60% maximum.
It is recommended that a crystal utilizing matching parallel load capacitors be used for the crystal
input/output signals (XI/XO). See Table 14.10 for crystal specifications.
Table 14.10 LAN9313/LAN9313i Crystal Specifications
PARAMETER
Crystal Cut
Crystal Oscillation Mode
Crystal Calibration Mode
Frequency
Frequency Tolerance @ 25oC
Frequency Stability Over Temp
Frequency Deviation Over Time
Total Allowable PPM Budget
Shunt Capacitance
Load Capacitance
Drive Level
Equivalent Series Resistance
Operating Temperature Range
SYMBOL
Ffund
Ftol
Ftemp
Fage
CO
CL
PW
R1
n/a XI Pin Capacitance
n/a XO Pin Capacitance
MIN
NOM
MAX
AT, typ
Fundamental Mode
Parallel Resonant Mode
-
25.000
-
-
-
+/-50
-
-
+/-50
-
+/-3 to 5
-
-
-
+/-50
-
7 typ
-
-
20 typ
-
0.5
-
-
-
-
30
0
-
+70Note 1
4.16
-
3 typ
-
-
3 typ
-
UNITS
MHz
PPM
PPM
PPM
PPM
pF
pF
mW
Ohm
oC
pF
pF
NOTES
Note 14.12
Note 14.12
Note 14.13
Note 14.14
Note 14.15
Note 14.15
Note 14.12 The maximum allowable values for Frequency Tolerance and Frequency Stability are
application dependant. Since any particular application must meet the IEEE +/-50 PPM
Total PPM Budget, the combination of these two values must be approximately +/-45 PPM
(allowing for aging).
Note 14.13 Frequency Deviation Over Time is also referred to as Aging.
Note 14.14 The total deviation for the Transmitter Clock Frequency is specified by IEEE 802.3 as
+/- 50 PPM.
Note 14.15 This number includes the pad, the bond wire and the lead frame. PCB capacitance is not
included in this value. The XO/XI pin and PCB capacitance values are required to
accurately calculate the value of the two external load capacitors. These two external load
capacitors determine the accuracy of the 25.000 MHz frequency.
Note 14.16 +70oC for commercial version (LAN9313), +85oC for industrial version (LAN9313I)
Revision 1.2 (04-08-08)
394
DATASHEET
SMSC LAN9313/LAN9313i