ISL78610 Datasheet, PDF (83/98 Pages) Intersil Corporation – Multi-Cell Li-Ion Battery Manager | |||
|
◁ |
ISL78610
Register Descriptions
Cell Voltage Data
BASE ADDR
ADDRESS
(PAGE) ACCESS RANGE
DESCRIPTION
3âb001
Read Only 6âh00 - 6âh0C Measured cell voltage and pack voltage values. Address 001111 accesses all cell and Pack Voltage data with
and 6âh0F one read operation. See Figure 70D on page 60.
Cell values are output as 13-bit signed integers with the 14th bit (MSB) denoting the sign, (e.g., positive full
scale is 14âh1FFF, 8191 decimal, negative full scale is 14âh2000, 8192 decimal). VBAT is a 14-bit unsigned
integer.
ACCESS
Read Only
PAGE
ADDR
3âb001
REGISTER
ADDRESS
6âh00 VBAT Voltage
6âh01 Cell 1 Voltage
6âh02 Cell 2 Voltage
6âh03 Cell 3 Voltage
6âh04 Cell 4 Voltage
6âh05 Cell 5 Voltage
6âh06 Cell 6 Voltage
6âh07 Cell 7 Voltage
6âh08 Cell 8 Voltage
6âh09 Cell 9 Voltage
6âh0A Cell 10 Voltage
6âh0B Cell 11 Voltage
6âh0C Cell 12 Voltage
6âh0F Read all cell voltages
DESCRIPTION
VCx
=
-ï¨--H-----E----X-----v---a-----l--u----e----1----0------â-----1----6----3----8----4-----ï©----ï´-----2------ï´-----2----.--5--
8192
ifï¼HEXvalue10 ï³ 8191
VCx = -H---E----X---v---a---l--u---e---1---0-----ï´-----2----ï´----2----.-5-
8192
ifï¼HEXvalue10 ï¼ 8191
VBAT = H------E------X-----v----a-----l---u-----e-----1-----0------ï´-------1-----5-----.--9-----3----5-----0-----7-----8-----4-------ï´------2-----.--5----
8192
Temperature Data, Secondary Voltage Reference Data, Scan Count
BASE ADDR
(PAGE)
ACCESS
ADDRESS
RANGE
DESCRIPTION
3âb001
See 6âh10 - 6âh16 Measured temperature, Secondary reference, Scan Count. Address 011111 accesses all these data in a
individual and 6âh1F continuous read (see Figure 70D on page 60). Temperature and reference values are output as 14-bit
register
unsigned integers, (e.g., full scale is 14âh3FFF (16383 decimal)).
Vtemp = -H---E----X---v---a---l--u---e---1---0-----ï´-----2---.-5--
16384
ACCESS
Read Only
PAGE
ADDR
3âb001
REGISTER
ADDRESS
DESCRIPTION
6âh10 Internal temperature reading.
6âh11 External temperature input 1 reading.
6âh12 External temperature input 2 reading.
6âh13 External temperature input 3 reading.
6âh14 External temperature input 4 reading.
6âh15 Reference voltage (raw ADC) value. Use to calculate corrected reference value using reference coefficient data.
See Page 2 data, address 6âh38 â 6âh3A.