Register Descriptions
Cell Voltage Data
BASE ADDR
ADDRESS
(PAGE) ACCESS RANGE
DESCRIPTION
3’b001
Read Only 6’h00 - 6’h0C Measured cell voltage and pack voltage values. Address 001111 accesses all cell and Pack Voltage data with
and 6’h0F one read operation. See Figure 70D on page 60.
Cell values are output as 13-bit signed integers with the 14th bit (MSB) denoting the sign, (e.g., positive full
scale is 14’h1FFF, 8191 decimal, negative full scale is 14’h2000, 8192 decimal). VBAT is a 14-bit unsigned
integer.
ACCESS
Read Only
PAGE
ADDR
3’b001
REGISTER
ADDRESS
6’h00 VBAT Voltage
6’h01 Cell 1 Voltage
6’h02 Cell 2 Voltage
6’h03 Cell 3 Voltage
6’h04 Cell 4 Voltage
6’h05 Cell 5 Voltage
6’h06 Cell 6 Voltage
6’h07 Cell 7 Voltage
6’h08 Cell 8 Voltage
6’h09 Cell 9 Voltage
6’h0A Cell 10 Voltage
6’h0B Cell 11 Voltage
6’h0C Cell 12 Voltage
6’h0F Read all cell voltages
DESCRIPTION
VCx
=
---H-----E----X-----v---a-----l--u----e----1----0------–-----1----6----3----8----4--------------2-----------2----.--5--
8192
ifHEXvalue10  8191
VCx = -H---E----X---v---a---l--u---e---1---0----------2--------2----.-5-
8192
ifHEXvalue10  8191
VBAT = H------E------X-----v----a-----l---u-----e-----1-----0-------------1-----5-----.--9-----3----5-----0-----7-----8-----4-------------2-----.--5----
8192
Temperature Data, Secondary Voltage Reference Data, Scan Count
BASE ADDR
(PAGE)
ACCESS
ADDRESS
RANGE
DESCRIPTION
3’b001
See 6’h10 - 6’h16 Measured temperature, Secondary reference, Scan Count. Address 011111 accesses all these data in a
individual and 6’h1F continuous read (see Figure 70D on page 60). Temperature and reference values are output as 14-bit
register
unsigned integers, (e.g., full scale is 14’h3FFF (16383 decimal)).
Vtemp = -H---E----X---v---a---l--u---e---1---0----------2---.-5--
16384
ACCESS
Read Only
PAGE
ADDR
3’b001
REGISTER
ADDRESS
DESCRIPTION
6’h10 Internal temperature reading.
6’h11 External temperature input 1 reading.
6’h12 External temperature input 2 reading.
6’h13 External temperature input 3 reading.
6’h14 External temperature input 4 reading.
6’h15 Reference voltage (raw ADC) value. Use to calculate corrected reference value using reference coefficient data.
See Page 2 data, address 6’h38 – 6’h3A.