Electrical Specifications VBAT = 6 to 60V, TA = -20°C to +85°C, unless otherwise specified. Biasing setup as in
Figure 45 on page 26 or equivalent. (Continued)
PARAMETER
SYMBOL
TEST CONDITIONS
MIN
(Note 8) TYP
Supply Current Specifications
VBAT Supply Current
IVBAT Non-daisy chain configuration. Device
6V
35
enabled. No communications, ADC,
measurement or open-wire detection activity. 39.6V
64
60V 10
73
IVBATMASTER Daisy chain configuration – master device.
6V
530
Enabled. No communications, ADC,
measurement or open-wire detection activity. 39.6V
680
60V 550
750
Peak current when daisy chain transmitting
18
IVBATMID
Daisy chain configuration – mid stack device.
Enabled. No communications, ADC,
measurement or open-wire detection activity.
6V
39.6V
60V
1000
1020
1250
1400
Peak current when daisy chain transmitting
18
IVBATTOP Daisy chain configuration – top device.
6V
530
Enabled. No communications, ADC,
measurement or open-wire detection activity. 39.6V
680
60V 550
750
Peak current when daisy chain transmitting
18
IVBATSLEEP1 Sleep mode
(EN = 1, daisy chain configuration).
20
35
IVBATSLEEP2 Sleep mode
(EN = 1, stand-alone, non-daisy chain)
13
20
IVBATSHDN Shutdown. device “off” (EN = 0)
(Daisy chain and non-daisy chain configurations)
6
15
VBAT Supply Current Tracking. Sleep
IVBATΔSLEEP EN = 1, daisy chain Sleep mode configuration.
0
Mode
VBAT current difference between any two devices
operating at the same temperature and supply
voltage.
V3P3 Regulator Voltage (Normal)
V3P3 Regulator Voltage (Sleep)
V3P3 Supply Current
V3P3N
V3P3S
IV3P3
EN = 1, Load current range 0 to 5 mA.
VBAT = 39.6V
EN = 1, Load current range. No load. (SLEEP).
VBAT = 39.6V
Device Enabled
No measurement activity, normal mode
3.2
3.35
2.7
0.7
1
VREF Reference Voltage
VDDEXT Switch Resistance
VCC Supply Current
VREF EN = 1, no load, normal mode
2.5
RVDDEXT Switch “On” resistance, VBAT = 39.6V
12
IVCC
Device enabled (EN = 1). Stand-alone or daisy
2.00
3.25
configuration. No ADC or daisy chain communications
active.
IVCCACTIVE1 Device enabled (EN = 1). Stand-alone or daisy
configuration. Average current during 16ms Scan
Continuous operation. VBAT = 39.6V
IVCCSLEEP Device enabled (EN = 1). Sleep mode. VBAT = 39.6V
IVCCSHDN Device disabled (EN = 0). Shutdown mode.
6.0
2.4
0
1.2
MAX
(Note 8)
96
1000
1700
1000
50
50
54
10.5
3.5
1.3
5.00
9.0
UNIT
µA
µA
µA
µA
µA
µA
mA
µA
µA
µA
mA
µA
µA
µA
mA
µA
µA
µA
µA
V
V
mA
V
Ω
mA
mA
µA
µA