English
Language : 

ISL78610 Datasheet, PDF (59/98 Pages) Intersil Corporation – Multi-Cell Li-Ion Battery Manager
ISL78610
DEVICE
ADDRESS
(23, 20)
PAGE
(18, 16)
DATA
ADDRESS
(15, 10)
ZERO
(9, 4)
CRC
(3, 0)
100100110000010000001111
MSB
BYTE 2
BYTE 1
BYTE 0
LSB
FIGURE 69C. DEVICE LEVEL COMMAND: DEVICE 9, SCAN VOLTAGES
DEVICE
ADDRESS
(23, 20)
PAGE
(18, 16)
DATA
ADDRESS
(15, 10)
ZERO
(9, 4)
CRC
(3, 0)
100100010001110000001100
MSB
BYTE 2
BYTE 1
BYTE 0
LSB
FIGURE 69D. DEVICE READ: DEVICE 9, GET CELL 7 DATA
DEVICE
ADDRESS
(23, 20)
PAGE
(18, 16)
DATA
ADDRESS
(15, 10)
ELEMENT
ADDRESS
(9, 4)
CRC
(3, 0)
010000110010000001010101
MSB
BYTE 2
BYTE 1
BYTE 0
LSB
FIGURE 69E. ELEMENT LEVEL COMMAND: DEVICE 4, MEASURE CELL 5 VOLTAGE
DEVICE
ADDRESS
(23, 20)
PAGE
(18, 16)
DATA
ADDRESS
(15, 10)
DEVICE
COUNT
(9, 4)
CRC
(3, 0)
000000110010010000000100
MSB
BYTE 2
BYTE 1
BYTE 0
LSB
FIGURE 69F. IDENTIFY COMMAND
DEVICE
ADDRESS
(31, 28)
PAGE
(26, 24)
DATA
ADDRESS
(23, 18)
DATA
(17, 4)
CRC
(3, 0)
0 111 1010 0100 1 00 0 1 11 1 1 11 11 11 11 0 00
MSB
BYTE 3
BYTE 2
BYTE 1
BYTE 0
LSB
FIGURE 69G. DEVICE WRITE: DEVICE 7, WRITE EXTERNAL TEMPERATURE LIMIT = 14’h0FFF
FIGURE 69. DAISY CHAIN DEVICE READ AND WRITE EXAMPLES
Submit Document Feedback 59
FN8830.1
June 16, 2016