English
Language : 

MC908AB32CFUE Datasheet, PDF (182/392 Pages) Freescale Semiconductor, Inc – Microcontrollers
Timer Interface Module A (TIMA)
11.7.1 Wait Mode
The TIMA remains active after the execution of a WAIT instruction. In
wait mode the TIMA registers are not accessible by the CPU. Any
enabled CPU interrupt request from the TIMA can bring the MCU out of
wait mode.
If TIMA functions are not required during wait mode, reduce power
consumption by stopping the TIMA before executing the WAIT
instruction.
11.7.2 Stop Mode
The TIMA is inactive after the execution of a STOP instruction. The
STOP instruction does not affect register conditions or the state of the
TIMA counter. TIMA operation resumes when the MCU exit stop mode
after an external interrupt.
11.8 TIMA During Break Interrupts
A break interrupt stops the TIMA counter.
The system integration module (SIM) controls whether status bits in
other modules can be cleared during the break state. The BCFE bit in
the SIM break flag control register (SBFCR) enables software to clear
status bits during the break state. See 8.8.3 SIM Break Flag Control
Register.
To allow software to clear status bits during a break interrupt, write a
logic one to the BCFE bit. If a status bit is cleared during the break state,
it remains cleared when the MCU exits the break state.
To protect status bits during the break state, write a logic zero to the
BCFE bit. With BCFE at logic zero (its default state), software can read
and write I/O registers during the break state without affecting status
bits. Some status bits have a two-step read/write clearing procedure. If
software does the first step on such a bit before the break, the bit cannot
change during the break state as long as BCFE is at logic zero. After the
break, doing the second step clears the status bit.
Technical Data
182
Timer Interface Module A (TIMA)
MC68HC908AB32 — Rev. 1.1
Freescale Semiconductor