English
Language : 

MC908AB32CFUE Datasheet, PDF (145/392 Pages) Freescale Semiconductor, Inc – Microcontrollers
Clock Generator Module (CGM)
PLLIE — PLL Interrupt Enable Bit
This read/write bit enables the PLL to generate an interrupt request
when the LOCK bit toggles, setting the PLL flag, PLLF. When the
AUTO bit in the PLL bandwidth control register (PBWC) is clear,
PLLIE cannot be written and reads as 0. Reset clears the PLLIE bit.
1 = PLL interrupts enabled
0 = PLL interrupts disabled
PLLF — PLL Interrupt Flag Bit
This read-only bit is set whenever the LOCK bit toggles. PLLF
generates an interrupt request if the PLLIE bit is set also. PLLF
always reads as 0 when the AUTO bit in the PLL bandwidth control
register (PBWC) is clear. The PLLF bit should be cleared by reading
the PLL control register. Reset clears the PLLF bit.
1 = Change in lock condition
0 = No change in lock condition
NOTE: The PLLF bit should not be inadvertently cleared. Any read or read-
modify-write operation on the PLL control register clears the PLLF bit.
PLLON — PLL On Bit
This read/write bit activates the PLL and enables the VCO clock,
CGMVCLK. PLLON cannot be cleared if the VCO clock is driving the
base clock, CGMOUT (BCS = 1). See 9.4.3 Base Clock Selector
Circuit. Reset sets this bit so that the loop can stabilize as the MCU
is powering up.
1 = PLL on
0 = PLL off
BCS — Base Clock Select Bit
This read/write bit selects either the crystal oscillator output,
CGMXCLK, or the VCO clock, CGMVCLK, as the source of the CGM
output, CGMOUT. CGMOUT frequency is one-half the frequency of
the selected clock. BCS cannot be set while the PLLON bit is clear.
After toggling BCS, it may take up to three CGMXCLK and three
CGMVCLK cycles to complete the transition from one source clock to
MC68HC908AB32 — Rev. 1.1
Freescale Semiconductor
Clock Generator Module (CGM)
Technical Data
145