4.9.3 Set7.Reg2 - Remote Infrared Config Register (RIR_CFG)
Reg.
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
RIR_CFG
Default Value
P_PNB
0
SMP_M
0
RXCFS
0
-
TX_CFS
0
0
Bit 2
RX_DM
0
Bit 1
Bit 0
TX_MM1 TX_MM0
0
0
Bit 7:
P_PNB: Programming Pulse Number Coding.
Write a 1 to select programming pulse number coding. The code format is defined as
follows.
(Number of bits) - 1
B7 B6 B5 B4 B3 B2 B1 B0
Bit value
Bit 6:
Bit 5:
Bit 4:
Bit 3:
Bit 2:
If the bit value is set to 0, the high pulse will be transmitted/received. If the bit value is
set to 1, then no energy will be transmitted/received.
SMP_M - Sampling Mode.
To select receiver sampling mode.
When set to 0 then uses T-period sampling, that the T-period is programmed IR baud
rate.
When set to 1, programmed baud rate will be used to do oversampling.
RXCFS - Receiver Carry Frequency Select
RXCFS
Selected Frequency
0
30K ~ 56K Hz
1
400K ~ 480K Hz
Reserved, write 0.
TX_CFS - Transmitter Carry Frequency Select.
Select low speed or high speed transmitter carry frequency.
TX_FCS
Selected Frequency
0
30K ~ 56K Hz
1
400K ~ 480K Hz
RX_DM - Receiver Demodulation Mode.
RX_DM
Demodulation Mode
0
Enable internal decoder
1
Disable internal decoder
- 80 -
Publication Release Date:April 1998