English
Language : 

W83977ATF Datasheet, PDF (115/207 Pages) Winbond – WINBOND I/O
12.3.6 Parallel Port FIFO Timing Parameters
PARAMETER
DATA Valid to nSTROBE Active
nSTROBE Active Pulse Width
DATA Hold from nSTROBE Inactive
BUSY Inactive to PD Inactive
BUSY Inactive to nSTROBE Active
nSTROBE Active to BUSY Active
W83977ATF
PRELIMINARY
SYMBOL
t1
t2
t3
t4
t5
t6
MIN.
600
600
450
80
680
MAX.
500
UNIT
nS
nS
nS
nS
nS
nS
12.3.7 ECP Parallel Port Forward Timing Parameters
PARAMETER
nAUTOFD Valid to nSTROBE Asserted
PD Valid to nSTROBE Asserted
BUSY Deasserted to nAUTOFD Changed
BUSY Deasserted to PD Changed
nSTROBE Deasserted to BUSY Deasserted
BUSY Deasserted to nSTROBE Asserted
nSTROBE Asserted to BUSY Asserted
BUSY Asserted to nSTROBE Deasserted
SYMBOL
t1
t2
t3
t4
t5
t6
t7
t8
MIN.
0
0
80
80
0
80
0
80
MAX.
60
60
180
180
200
180
UNIT
nS
nS
nS
nS
nS
nS
nS
nS
12.3.8 ECP Parallel Port Reverse Timing Parameters
PARAMETER
PD Valid to nACK Asserted
nAUTOFD Deasserted to PD Changed
nAUTOFD Asserted to nACK Asserted
nAUTOFD Deasserted to nACK Deasserted
nACK Deasserted to nAUTOFD Asserted
PD Changed to nAUTOFD Deasserted
SYMBOL
t1
t2
t3
t4
t5
t6
MIN.
0
0
0
0
80
80
MAX.
200
200
UNIT
nS
nS
nS
nS
nS
nS
Publication Release Date: April 1998
170-