English
Language : 

W25N01GVZEIT-TR Datasheet, PDF (37/68 Pages) Winbond – 3V 1G-BIT SERIAL SLC NAND FLASH MEMORY WITH DUAL/QUAD SPI BUFFER READ & CONTINUOUS READ
W25N01GVxxIG/IT
8.2.12 Quad Load Program Data (32h) / Quad Random Load Program Data (34h)
The “Quad Load Program Data” and “Quad Random Load Program Data” instructions are identical to the
“Load Program Data” and “Random Load Program Data” in terms of operation sequence and functionality.
The only difference is that “Quad Load” instructions will input the data bytes from all four IO pins instead of
the single DI pin. This method will significantly shorten the data input time when a large amount of data
needs to be loaded into the Data Buffer. The instruction sequence is illustrated in Figure 16.
Both “Quad Load Program Data” and “Quad Random Load Program Data” instructions share the same
command sequence. The difference is that “Quad Load Program Data” instruction will reset the unused the
data bytes in the Data Buffer to FFh value, while “Quad Random Load Program Data” instruction will only
update the data bytes that are specified by the command input sequence, the rest of the Data Buffer will
remain unchanged.
When WP-E bit in the Status Register is set to a 1, all Quad SPI instructions are disabled.
Figure 16. Quad Load / Quad Random Load Program Data Instruction
- 36 -
Publication Release Date: March 21, 2016
Revision G