English
Language : 

CDCE62002 Datasheet, PDF (15/49 Pages) Texas Instruments – Four Output Clock Generator/Jitter Cleaner With Integrated Dual VCOs
CDCE62002
www.ti.com.............................................................................................................................................................. SCAS882A – JUNE 2009 – REVISED JULY 2009
OUTPUT TO OUTPUT ISOLATION
Measurement Method
1. Connect output 1 to the phase noise and Spectrum analyzer.
2. Measure spurious on Outputs 1.
3. Enable aggressor channel 0
4. Measure spurious on Output 1
5. The difference between the spurious levels of Outputs 1 before and after enabling the aggressor channel determine the output-to-output
isolation performance recorded.
Table 4. Output to Output Isolation
WORST CASE SPUR
The Output to Output Isolation was tested at 3.3V supply and 25°C ambient temperature (Default Configuration):
Output 1
Measured Channel
In LVDS Signaling at 125MHz
-70
Output 0
Aggressor Channel
LVPECL 156.25MHz
UNIT
dB
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): CDCE62002
Submit Documentation Feedback
15