English
Language : 

CD00191174 Datasheet, PDF (78/112 Pages) STMicroelectronics – High-density access line, ARM-based 32-bit MCU
Electrical characteristics
STM32F101xC, STM32F101xD, STM32F101xE
Electromagnetic Interference (EMI)
The electromagnetic field emitted by the device is monitored while a simple application is
executed (toggling 2 LEDs through the I/O ports). This emission test is compliant with
IEC 61967-2 standard which specifies the test board and the pin loading.
Table 42. EMI characteristics
Symbol Parameter
Conditions
Monitored
frequency band
Max vs. [fHSE/fHCLK]
8/36 MHz
Unit
0.1 MHz to 30 MHz
8
SEMI
Peak level
VDD = 3.3 V, TA = 25 °C,
LQFP144 package
compliant with
30 MHz to 130 MHz
130 MHz to 1 GHz
27
26
IEC 61967-2
SAE EMI Level
4
dBµV
-
5.3.12
Absolute maximum ratings (electrical sensitivity)
Based on three different tests (ESD, LU) using specific measurement methods, the device is
stressed in order to determine its performance in terms of electrical sensitivity.
Electrostatic discharge (ESD)
Electrostatic discharges (a positive then a negative pulse separated by 1 second) are
applied to the pins of each sample according to each pin combination. The sample size
depends on the number of supply pins in the device (3 parts × (n+1) supply pins). This test
conforms to the JESD22-A114/C101 standard.
Table 43. ESD absolute maximum ratings
Symbol
Ratings
Conditions
Class Maximum value(1) Unit
VESD(HBM)
Electrostatic discharge
voltage (human body model)
TA = +25 °C, conforming
to JESD22-A114
2
VESD(CDM)
Electrostatic discharge
TA = +25 °C, conforming
voltage (charge device model) to JESD22-C101
II
2000
V
500
1. Based on characterization results, not tested in production.
Static latch-up
Two complementary static tests are required on six parts to assess the latch-up
performance:
● A supply overvoltage is applied to each power supply pin
● A current injection is applied to each input, output and configurable I/O pin
These tests are compliant with EIA/JESD 78 IC latch-up standard.
Table 44. Electrical sensitivities
Symbol
Parameter
Conditions
LU
Static latch-up class TA = +85 °C conforming to JESD78A
Class
II level A
78/112
Doc ID 14610 Rev 8