English
Language : 

RX21A_15 Datasheet, PDF (88/132 Pages) Renesas Technology Corp – Renesas MCUs
RX21A Group
5. Electrical Characteristics
5.4.2
Timing of Recovery from Low Power Consumption Modes
Table 5.28 Timing of Recovery from Low Power Consumption Modes
Conditions: VCC = AVCC0 = AVCCA = 1.8 to 3.6 V, VSS = AVSS0 = AVSSA = VREFL = VREFL0 = VREFDSL = 0 V,
Ta = –40 to +105°C
Item
Symbol Min.
Typ.
Max.
Unit
Test
Conditions
Recovery time Crystal resonator Main clock oscillator
after
connected to
operating
tSBYMC
—
3
—
ms Figure 5.37
cancellation of
software
standby mode
main clock
oscillator*2
Main clock oscillator and
tSBYPC
—
3.5
—
ms
PLL circuit operating
(flash memory, External clock
HOCO power input to main
Main clock oscillator
operating
tSBYEX
10
—
—
µs
supplied)
clock oscillator
(SOFTCUT[2:0]
bits = 000b)*1
Main clock oscillator and
PLL circuit operating
tSBYPE
0.5
—
Sub-clock oscillator operating
tSBYSC
2*3
—
—
ms
—
s
HOCO clock oscillator operating
tSBYHO
—
—
500
µs
LOCO clock oscillator operating
tSBYLO
—
—
90
µs
Recovery time Crystal resonator Main clock oscillator
after
connected to
operating
tSBYMC
—
3
—
ms Figure 5.37
cancellation of
software
standby mode
main clock
oscillator*2
Main clock oscillator and
tSBYPC
—
3.5
—
ms
PLL circuit operating
(flash memory External clock
power supplied, input to main
Main clock oscillator
operating
tSBYEX
40
—
—
µs
HOCO power clock oscillator
not supplied)
(SOFTCUT[2:0]
Main clock oscillator and
PLL circuit operating
tSBYPE
0.5
—
bits = 110b)*1 Sub-clock oscillator operating
tSBYSC
2*3
—
—
ms
—
s
HOCO clock oscillator operating
tSBYHO
—
—
1.2
ms
LOCO clock oscillator operating
tSBYLO
—
—
90
µs
Recovery time after cancellation of deep software standby mode tDSBY
—
—
8
ms Figure 5.38
Wait time after cancellation of deep software standby mode
tDSBYWT
—
—
0.8
ms
Note 1. The recovery time varies depending on the state of each oscillator when the WAIT instruction is executed. The recovery time
when multiple oscillators are operating varies depending on the operating state of the oscillators that are not selected as the
system clock source, and depends on the time set in the wait control registers corresponding to the oscillators.
Note 2. The indicated value is measured for an 8 MHz crystal resonator.
Note 3. When RCR3.RTCEN = 1, the time will be the time set in the SOSCWTCR register minus 2 s.
R01DS0129EJ0110 Rev.1.10
Aug 28, 2014
Page 88 of 132