80C286
AC Electrical Specifications 82C284 and 82C288 Timing Specifications are given for reference only and no guarantee is implied.
82C284 Timing
SYMBOL
PARAMETER
TIMING REQUIREMENTS
11
SRDY/SRDYEN Setup Time
12
SRDY/SRDYEN Hold Time
13
ARDY/ARDYEN Setup Time
14
ARDY/ARDYEN Hold Time
TIMING RESPONSES
19
PCLK Delay
10MHz
MIN MAX
12.5MHz
MIN MAX
15
-
15
-
2
-
2
-
5
-
5
-
30
-
25
-
0
20
0
16
NOTE:
43. These times are given for testing purposes to ensure a predetermined action.
16MHz
MIN MAX
UNIT
TEST
CONDITION
10
-
ns
1
-
ns
3
-
ns (Note 43)
20
-
ns (Note 43)
0
15
ns CL = 75pF,
IOL = 5mA,
IOH = 1mA
82C288 Timing
10MHz
12.5MHz
SYMBOL
PARAMETER
MIN MAX MIN MAX
TIMING REQUIREMENTS
12
CMDLY Setup Time
15
-
15
-
13
CMDLY Hold Time
1
-
1
-
TIMING RESPONSES
16
ALE Active Delay
1
16
1
16
17
ALE Inactive Delay
-
19
-
19
19
DT/R Read Active Delay
-
23
-
23
20
DEN Read Active Delay
-
21
-
21
21
DEN Read Inactive Delay
3
23
3
21
22
DT/R Read Inactive Delay
5
24
5
18
23
DEN Write Active Delay
-
23
-
23
24
DEN Write Inactive Delay
3
23
3
23
29
Command Active Delay from CLK
3
21
3
21
30
Command Inactive Delay from CLK
3
20
3
20
NOTE:
44. These times are given for testing purposes to ensure a predetermined action.
16MHz
MIN MAX
UNIT
TEST
CONDITION
10
-
ns
0
-
ns
1
12
ns
-
15
ns
-
18
ns CL = 150pF
-
16
ns IOL = 16mA Max
5
14
ns IOL = 1mA Max
5
14
ns
-
17
ns
3
15
ns
3
15
ns CL = 300pF
3
15
ns IOL = 32mA Max
46
|
▷ |