English
Language : 

X9000 Datasheet, PDF (26/77 Pages) Intel Corporation – Core2 Duo Processor and Core2 Extreme Processor on 45-nm Process
Electrical Specifications
Table 2.
3.4
Voltage Identification Definition (Sheet 4 of 4)
VID6
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
VID5
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
VID4
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
VID3
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
VID2
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
VID1
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
VID0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
VCC (V)
0.2750
0.2625
0.2500
0.2375
0.2250
0.2125
0.2000
0.1875
0.1750
0.1625
0.1500
0.1375
0.1250
0.1125
0.1000
0.0875
0.0750
0.0625
0.0500
0.0375
0.0250
0.0125
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
Catastrophic Thermal Protection
The processor supports the THERMTRIP# signal for catastrophic thermal protection. An
external thermal sensor should also be used to protect the processor and the system
against excessive temperatures. Even with the activation of THERMTRIP#, which halts
all processor internal clocks and activity, leakage current can be high enough that the
processor cannot be protected in all conditions without the removal of power to the
processor. If the external thermal sensor detects a catastrophic processor temperature
of 125°C (maximum), or if the THERMTRIP# signal is asserted, the VCC supply to the
processor must be turned off within 500 ms to prevent permanent silicon damage due
to thermal runaway of the processor. THERMTRIP# functionality is not ensured if the
PWRGOOD signal is not asserted, and during package C6.
26
Datasheet