ICS1893 Datasheet, PDF (94/152 Pages) Integrated Circuit Systems – 3.3-V 10Base-T/100Base-TX Integrated PHYceiver™
ICS1893 Data Sheet - Release
Chapter 8 Management Register Set
8.12.5 100Base PLL Lock Error (bit 17.9)
The Phase-Locked Loop (PLL) Lock Error bit indicates to an STA whether the ICS1893 has ever
experienced a PLL Lock Error. A PLL Lock Error occurs when the PLL fails to lock onto the incoming
100Base data stream. If this bit is set to a logic:
• Zero, it indicates that a PLL Lock Error has not occurred since either the last read or reset of this register.
• One, it indicates that a PLL Lock Error has occurred since either the last read or reset of this register.
This bit is a latching high bit. (For more information on latching high and latching low bits, see Section
8.1.4.1, “Latching High Bits”and Section 8.1.4.2, “Latching Low Bits”.)
Note: This bit has no definition in 10Base-T mode.
8.12.6 False Carrier (bit 17.8)
The False Carrier bit indicates to an STA the detection of a False Carrier by the ICS1893 in 100Base mode.
A False Carrier occurs when the ICS1893 begins evaluating potential data on the incoming 100Base data
stream, only to learn that it was not a valid /J/K/. If this bit is set to a logic:
• Zero, it indicates a False Carrier has not been detected since either the last read or reset of this register.
• One, it indicates a False Carrier was detected since either the last read or reset of this register.
This bit is a latching high bit. (For more information on latching high and latching low bits, see Section
8.1.4.1, “Latching High Bits”and Section 8.1.4.2, “Latching Low Bits”.)
Note: This bit has no definition in 10Base-T mode.
8.12.7 Invalid Symbol (bit 17.7)
The Invalid Symbol bit indicates to an STA the detection of an Invalid Symbol in a 100Base data stream by
the ICS1893.
When the ICS1893 is receiving a packet, it examines each received Symbol to ensure the data is error free.
If an error occurs, the port indicates this condition to the MAC/repeater by asserting the RXER signal. In
addition, the ICS1893 sets its Invalid Symbol bit to logic one. Therefore, if this bit is set to a logic:
• Zero, it indicates an Invalid Symbol has not been detected since either the last read or reset of this
register.
• One, it indicates an Invalid Symbol was detected since either the last read or reset of this register.
This bit is a latching high bit. (For more information on latching high and latching low bits, see Section
8.1.4.1, “Latching High Bits”and Section 8.1.4.2, “Latching Low Bits”.)
Note: This bit has no definition in 10Base-T mode.
ICS1893 Rev C 6/6/00
Copyright © 2000, Integrated Circuit Systems, Inc.
All rights reserved.
94
June, 2000