Chapter 3 ICS1893 Enhanced Features
Table 3-1. Summary of Differences between ICS1890 and ICS1893 Registers
Register.
Bit(s)
ICS1890
Function
Default
ICS1893
Function
1.6 Reserved
3.9:4
3.3:0
Model Number
Revision Number
0b (always) Management Frame Preamble
Suppression
000010b Model Number
0011b
Revision Number
6.2
7.15:0
Next Page Able
Not applicable (N/A)
8.15:0 N/A
9.15:0
through
15.15:0
IEEE reserved.
18.15 Reserved
0b (always) Next Page Able
N/A
Auto-Negotiate Next Page
Transmit Register
N/A
Auto-Negotiate Next Page
Link Partner Ability
0000h
IEEE reserved.
Note: Although the default value is
changed, this response more
accurately reflects an MDIO
access to registers 9–15.
0b
Remote Jabber
19.1
20.15:0
through
31.15:0
Reserved
N/A
0b
Automatic 10Base-T Power Down
N/A
ICS test registers.
(There is no claim of backward
compatibility for these registers.)
Default
0b
000100b
0000b
1b
2001h
0000h
FFFFh
0b
1b
See specific
registers and
bits.
Note:
1. There are new registers and bits. For example:
a. Registers 7 and 8 are new (that is, the ICS1890 does not have these registers).
b. Registers 20 through 31 are new ICS test registers.
2. For some bits (such as the model number and revision number bits), the default values are changed.