For the case of page program
1) In section 3.2 it was explained that a number of consecutive partial program operations (NOP) is allowed within the
same page. In case this feature is used, the number of partial program operations occurring in the same EDC unit must
not exceed "one" (1). In other words, page program operations must be performed on the whole page, or on whole
EDC unit at a time.
2) "random data input" in a given EDC unit can be executed several times during one page program sequence, but data
insertion in each column address of each EDC unit must not exceed "one" (1).
For the case of copy back program
1) If random data input is applied in a given EDC unit, the data of the whole EDC unit must be inserted. In other words,
the EDC check is possible only if the whole EDC unit is modified during one copy back program sequence
2) "random data input" in a given EDC unit can be executed several times during one copy back sequence , but data
insertion in each column address of the EDC unit must not exceed "one" (1)
For the user which use Copy Back without EDC check, all the limitations described above do not apply.
Main Field (2,048 Byte)
Spare Field (64 Byte)
“A”area
(1st sector)
512 Byte
“B”area
(2nd sector)
512 Byte
“C”area
(3rd sector)
512 Byte
“D”area
(4th sector)
512 Byte
“E”area
(1st sector)
16 Byte
“F”area
(2nd sector)
16 Byte
“G”area
(3rd sector)
16 Byte
“H”area
(4th sector)
16 Byte
Table 8: page organization in EDC units (x8)
Sector
1st 528-Byte Sector
2nd 528-Byte Sector
3rd 528-Byte Sector
4th 528-Byte Sector
Main Field (Column 0~2047)
Area Name
Column Address
“A”
0~511
“B”
512~1023
“C”
1024~1535
“D”
1536~2047
Spare Field (Column 2048~2111)
Area Name
Column Address
“E”
2048~2063
“F”
2064~2079
“G”
2080~2095
“H”
2096~2111
Table 9: page organization in EDC units (x8)
“A”area
(1st sector)
256 words
“B”area
(2nd sector)
256 words
“C”area
(3rd sector)
256 words
“D”area
(4th sector)
256 words
“E”area
(1st sector)
8 words
“F”area
(2nd sector)
8 words
“G”area
(3rd sector)
8 words
“H”area
(4th sector)
8 words
Sector
1st 264-word Sector
2nd 264-word Sector
3rd 264-word Sector
4th 264-word Sector
Rev 1.4 / OCT. 2010
Table 10: page organization in EDC units (x16)
Main Field (Column 0~1023)
Area Name
Column Address
“A”
0~255
“B”
256~511
“C”
512~767
“D”
768~1023
Spare Field (Column 1024~1055)
Area Name
Column Address
“E”
1024~1031
“F”
1032~1039
“G”
1040~1047
“H”
1048~1055
Table 11: page organization in EDC units (x16)