C8051F326 Datasheet, PDF (64/140 Pages) List of Unclassifed Manufacturers – Full Speed USB, 16 kB Flash MCU Family | |||
|
◁ |
C8051F326/7
Table 7.1. Reset Electrical Characteristics
â40 to +85 °C unless otherwise specified.
Parameter
âF326 RST Output Voltage
âF327 RST Output Voltage
RST Input High Voltage*
Conditions
IOL = 8.5 mA; VIO = 2.7 to 3.6 V
Min Typ
â
â
IOL = TBD; VIO = 2.0V;
IOL = TBD; VIO = 2.7 to 3.6 V
â
â
0.7 x VIO â
Max
0.6
TBD
TBD
â
Units
V
V
V
RST Input Low Voltage*
â
â 0.3 x VIO V
âF326 RST Pullup Current
10
26
40
µA
âF327 RST Pullup Current
â
26
40
µA
VDD Monitor Threshold (VRST)
2.40 2.55 2.70
V
Missing Clock Detector Timeout Time from last system clock rising 100
240 500
µs
edge to reset initiation
Reset Time Delay
Delay between the release of any 5.0
â
â
µs
reset source and code execution
at location 0x0000
Minimum RST Low Time to
Generate a System Reset
15
â
â
µs
VDD Monitor Turn-on Time
100
â
â
µs
VDD Monitor Supply Current
â
45
TBD
µA
*Note: On 'F327 devices, VIO = VDD.