C8051F326/7
C2 Register Definition 15.3. REVID: C2 Revision ID
Reset Value
00000000
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
This read-only register returns the 8-bit revision ID: 0x01 (Revision B).
C2 Register Definition 15.4. FPCTL: C2 Flash Programming Control
Reset Value
00000000
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
Bits7–0
FPCTL: Flash Programming Control Register.
This register is used to enable Flash programming via the C2 interface. To enable C2 Flash
programming, the following codes must be written in order: 0x02, 0x01. Note that once C2
Flash programming is enabled, a system reset must be issued to resume normal operation.
C2 Register Definition 15.5. FPDAT: C2 Flash Programming Data
Reset Value
00000000
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
Bits7–0: FPDAT: C2 Flash Programming Data Register.
This register is used to pass Flash commands, addresses, and data during C2 Flash
accesses. Valid commands are listed below.
Code
0x06 Flash Block Read
0x07 Flash Block Write
0x08 Flash Page Erase
0x03 Device Erase
Command
138