English
Language : 

IBIS4-6600 Datasheet, PDF (39/63 Pages) Cypress Semiconductor – High resolution 6.6 M Pixel Rolling shutter CMOS Image sensor
IBIS4-6600
Datasheet
4 Timing diagrams
4.1 Sequencer control signals
There are 3 control signals that operate the image sensor:
• SYS_CLOCK
• Y_CLOCK
• Y_START
These control signals should be generated by the external system with following time
constraints to SYS_CLOCK (rising edge = active edge):
TSETUP >7.5 ns.
THOLD > 7.5 ns.
It is important that these signals are free of any glitches.
Figure 20: Relative timing of the 3 sequencer control signals
Figure 21 shows the recommended schematic for generating the control signals and to
avoid any timing problems.
Y_CLOCK
FF
Y_START
SYS_CLOCK_N
SYS_CLOCK
Figure 21: Recommended schematic for generating control signals
4.2 Basic frame and line timing
The basic frame and line timing of the IBIS4-6600 sensor is shown in Figure 21.
Cypress Semiconductor Corporation 3901 North First Street
San Jose, CA 95134
408-943-2600
Contact: info@Fillfactory.com Document #: 38-05708 Rev.**(Revision 1.3 )
Page 39 of 63