English
Language : 

AMIS-53000 Datasheet, PDF (68/99 Pages) AMI SEMICONDUCTOR – Frequency Agile Transceiver
AMIS-53000 Frequency Agile Transceiver
Data Sheet
Table 65: Housekeeping Config - 0X1B [27]
Bit Name
State Comment
HK Interval
7
Resolution
1
Five minute resolution setting
0
One second resolution setting
6 Wake
1
Issue interrupt and enable clock to external host/controller
0
5 Write EE
1
Current register data written to EE (performed after all Cal’s complete)*
0
4
Read INT
ADC Channels
1
0
Temp sensor and battery inputs converted
3
Read EXT
ADC Channels
1
0
EXT1 and EXT2 ADC inputs converted
2 Cal PLL
1
PLL calibration performed during housekeeping
0
1 Cal RC
1
RC oscillator calibration performed during housekeeping
0
0 Cal Kicker
1
Kicker calibration performed during housekeeping
0
Note: * Bit 5 is set high to allow the EE to be automatically written after a calibration is complete.
6.7.4.2. Housekeeping Interval
Sets the interval (time that the AMIS-53000 is in sleep mode) for the housekeeping routine.
Table 66: Housekeeping Interval - 0X1C [28]
Bit Name
Comment
7:0 HK_INT [7:0]
Housekeeping interval = (HK_INT+1)* (HK interval resolution)
6.8 Idle Return
Table 67: Idle Return
Register
Number (HEX) Name
0X00
Command
Code
0X04
Function
In most conditions, the AMIS-53000 must be returned to idle mode at
the end of a task by this command
This command is used to put the part back into idle mode. It should be used by the host to place the AMIS-53000 back into idle mode
after the AMIS-53000 has interrupted the host for reception of a packet in Sniff, or to end a housekeeping cycle.
AMI Semiconductor – Aug. 05, Rev. 1.0
68