English
Language : 

AMIS-53000 Datasheet, PDF (61/99 Pages) AMI SEMICONDUCTOR – Frequency Agile Transceiver
AMIS-53000 Frequency Agile Transceiver
Data Sheet
Table 52: Idle Config - 0X10 [16]
Bit Name
State
7:5 Wait timing between 111
INT and DSSN for
…
Sniff Receive
000
Wait timing between
11
4,3 idle instruction and
10
system clock shutoff 01
time
00
2
Housekeeping
Enable
1
0
1
1
Burst Enable
0
1
0
Sniff Enable
0
Comment
DSSN going active is delayed 8 bit times from INT
DSSN is immediately active after INT
System clock outputs 1024 clock cycles before shutdown after idle command
System clock outputs 512 clock cycles before shutdown after idle command
System clock outputs 256 clock cycles before shutdown after idle command
System clock immediately shuts down after idle command
Periodic housekeeping enabled (HK settings must be set)
Periodic Burst mode enabled (BURST settings must be set)
Periodic Sniff Mode enabled (Sniff settings must be set)
6.7.2. Sniff Mode Operation
Table 53: Sniff Mode Configuration
Register
Number (HEX) Name
0X0E
RX Config
0X10
Idle Config
Function
Bits
1
Force the receiver to not output Clk&Data < energy level
0
Set the receiver to wake when at energy level threshold
2
Enable periodic Sniff Mode
The quick start technology enables the AMIS-53000 to operate its receiver in a mode called Sniff Mode. As implemented in the
AMIS-53000, this Sniff Mode can wake the receiver and acquire the transmitted message in as little as 130 microseconds.
AMI Semiconductor – Aug. 05, Rev. 1.0
www.amis.com
Figure 40: Sniff Waveform
61