English
Language : 

AMIS-53000 Datasheet, PDF (64/99 Pages) AMI SEMICONDUCTOR – Frequency Agile Transceiver
AMIS-53000 Frequency Agile Transceiver
Data Sheet
Automatic Threshold Optimization in Sniff Mode
An option available in the Sniff Mode config register will enable the AMIS-53000 to automatically adjust the energy threshold of the
AMIS-53000 to optimize the sensitivity of the Sniff Mode. The target number of wake ups (register 0X2F) allows the user to specify a
value for the number of false wake ups the AMIS-53000 is allowed with the selected configuration of the Sniff Mode (by bits [4:3] in the
SNIFF_CONFIG register) number of Sniff cycles.
As an example:
If the number of Sniff cycles is set to 500 (Sniff config [Bit 4:3]),
If the target number of false wake ups is set to 50 (target number wake ups),
Then over the course of the next 500 Sniff cycles the radio is triggered falsely by energy:
More than 50 times, the threshold will be increased to reduce the sensitivity,
Less than 50 times, the threshold will be decreased to increase the sensitivity.
Using this option to set the threshold for energy detection can have a dramatic impact on the life of battery powered devices, as the
AMIS-53000 will adjust to changing levels of background noise while still maintaining maximum sensitivity, and not wasting power by
continually waking and processing background noise.
Additionally, the energy threshold setting can be monitored by an external host/controller. The amount the threshold will increase or
decrease is based on Table 57, with the order of the rows in the same order as the AMIS-53000 will evaluate the conditions.
Table 57: Auto Threshold Adjust
Condition
Select the number of Sniff cycles as the test period
Enter the desired number of false wake ups per
period
Then if wake ups/period > target
Then if wake ups/period < target
Adjustment
Note: a false wake up is when the receiver detects energy but fails to detect the ID in the
packet
Threshold is increased
Threshold is decreased
The threshold of the AMIS-53000 can vary over a wide range from one device to the next, due to design, manufacturing tolerances, and
environment changes; temperature and voltage. This automatic threshold optimization can be used to adjust the threshold by
monitoring the level of false wake ups due to background noise. The adjustment in this fashion can reduce the effects of design and
manufacturing on the threshold setting of the AMIS-53000.
Setup registers descriptions:
Target- Set a value for the allowed number of false wake ups desired.
Target Threshold
The number of false wake ups occurring during a period of time is used to automatically adjust the energy threshold in the Sniff
operation. This allows the AMIS-53000 to automatically adjust its input level to compensate for, manufacturing, components,
environment, temperature, and/or voltage.
Table 58: Target Wake Ups - 0X2F [47]
Bit Name
Comment
7:0 Target [7:0]
The number of wake-ups that the Sniff circuit will try to adjust the threshold to not have
more false wake ups or less missed signal detections. This register allows the number to
be 0 to 255, but this number should always be less than the number of Sniff count (Sniff
config bit 4:3).
AMI Semiconductor – Aug. 05, Rev. 1.0
64