English
Language : 

EP2S15 Datasheet, PDF (137/238 Pages) Altera Corporation – Stratix II Device Family
5. DC & Switching
Characteristics
SII51005-4.3
Operating
Conditions
Stratix® II devices are offered in both commercial and industrial grades.
Industrial devices are offered in -4 speed grades and commercial devices
are offered in -3 (fastest), -4, -5 speed grades.
Tables 5–1 through 5–32 provide information on absolute maximum
ratings, recommended operating conditions, DC electrical characteristics,
and other specifications for Stratix II devices.
Absolute Maximum Ratings
Table 5–1 contains the absolute maximum ratings for the Stratix II device
family.
Table 5–1. Stratix II Device Absolute Maximum Ratings Notes (1), (2), (3)
Symbol
Parameter
Conditions
Minimum Maximum Unit
VCCINT
VCCIO
VCCPD
VCCA
VCCD
VI
IOUT
TSTG
TJ
Supply voltage
With respect to ground
Supply voltage
With respect to ground
Supply voltage
With respect to ground
Analog power supply for
PLLs
With respect to ground
Digital power supply for PLLs With respect to ground
DC input voltage (4)
DC output current, per pin
Storage temperature
No bias
Junction temperature
BGA packages under bias
–0.5
–0.5
–0.5
–0.5
–0.5
–0.5
–25
–65
–55
1.8
V
4.6
V
4.6
V
1.8
V
1.8
V
4.6
V
40
mA
150
°C
125
°C
Notes to Tables 5–1
(1) See the Operating Requirements for Altera Devices Data Sheet.
(2) Conditions beyond those listed in Table 5–1 may cause permanent damage to a device. Additionally, device
operation at the absolute maximum ratings for extended periods of time may have adverse affects on the device.
(3) Supply voltage specifications apply to voltage readings taken at the device pins, not at the power supply.
(4) During transitions, the inputs may overshoot to the voltage shown in Table 5–2 based upon the input duty cycle.
The DC case is equivalent to 100% duty cycle. During transitions, the inputs may undershoot to –2.0 V for input
currents less than 100 mA and periods shorter than 20 ns.
Altera Corporation
5–1
May 2007