4) Read During RUNNING
a) Control Register read out ( during RUN )
It is possible to read out Control Registers in RUN mode. D7 ~ D1 control register values are output at the
falling edge of SCLK after a command code is input. As no register exists at D0 location, “0” is always
output until the 16th rising edge of SCLK.
Note) when D0 data is taken at the 16th rising edge of SCLK, it is not necessarily always “0”, so please
ignore the D0 value (as it is indeterminate after the 16th rising edge of SCLK).
Data transfer procedure
c Command code 70h,72h,74h,76h,78h,7Ah,7Ch,D8h,DAh,DCh
note ) 50h,54h,58h are not used as they are for testing.
For each Bit function, please refer to section (2) Control Register Settings.
S_RESET =H
RQ
SCLK
SI
SO
70h(example)
D7yyyyD1
74h(example)
D7yyyyD1
Example of Control Register Read
[MS0296-E-00]