W83787IF
(6) Write Deleted Data
PHASE R/W
D7 D6 D5 D4 D3 D2 D1 D0
Command W
W
MT MFM 0 0 1 0 0 1
0 0 0 0 0 HDS DS1 DS0
W
---------------------- C ------------------------
W
---------------------- H ------------------------
W
---------------------- R ------------------------
W
---------------------- N ------------------------
W
-------------------- EOT -----------------------
W
-------------------- GPL -----------------------
W
-------------------- DTL -----------------------
Execution
Result
R
-------------------- ST0 -----------------------
R
-------------------- ST1 -----------------------
R
-------------------- ST2 -----------------------
R
---------------------- C ------------------------
R
---------------------- H ------------------------
R
---------------------- R ------------------------
R
---------------------- N ------------------------
REMARKS
Command codes
Sector ID information prior
to command execution
Data transfer between the
FDD and system
Status information after
command execution
Sector ID information after
command execution