English
Language : 

MSP430F6779A Datasheet, PDF (41/176 Pages) Texas Instruments – Polyphase Metering SoCs
www.ti.com
MSP430F6779A, MSP430F6778A, MSP430F6777A, MSP430F6776A, MSP430F6775A
MSP430F6769A, MSP430F6768A, MSP430F6767A, MSP430F6766A, MSP430F6765A
MSP430F6749A, MSP430F6748A, MSP430F6747A, MSP430F6746A, MSP430F6745A
SLAS982 – MAY 2014
5.8.3 Auxiliary Supplies
Table 5-18. Auxiliary Supplies, Recommended Operating Conditions
over operating free-air temperature range (unless otherwise noted)
MIN NOM MAX UNIT
VCC
Supply voltage range for all supplies at pins DVCC, AVCC, AUXVCC1, AUXVCC2,
AUXVCC3
1.8
3.6 V
PMMCOREVx = 0
1.8
3.6
VDSYS
Digital system supply voltage range,
VDSYS = VCC – RON × ILOAD
PMMCOREVx = 1
PMMCOREVx = 2
2.0
3.6
V
2.2
3.6
PMMCOREVx = 3
2.4
3.6
VASYS
TA
TA,HTOL
CVCC,CAUX1/2
CVSYS
CVCORE
CAUX3
Analog system supply voltage range, VASYS = VCC – RON × ILOAD
Ambient temperature range
Ambient temperature during HTOL (module should be functional during HTOL)
Recommended capacitor at pins DVCC, AVCC, AUXVCC1, AUXVCC2
Recommended capacitor at pins VDSYS1, VDSYS2 and VASYS1, VASYS2
Recommended capacitance at pin VCORE
Recommended capacitor at pin AUXVCC3
See modules
V
-40
85 °C
150 °C
4.7
µF
4.7
µF
0.47
µF
0.47
µF
Table 5-19. Auxiliary Supplies, AUXVCC3 (Backup Subsystem) Currents
over operating free-air temperature range (unless otherwise noted)
IAUX3,RTCon
PARAMETER
AUXVCC3 current with
RTC enabled
TEST CONDITIONS
RTC and 32-kHz oscillator in
backup subsystem enabled
VCC
TA
MIN TYP
25°C
3V
85°C
IAUX3,RTCoff
AUXVCC3 current with RTC and 32-kHz oscillator in
RTC disabled
backup subsystem disabled
25°C
3V
85°C
MAX
0.86
1.2
120
220
UNIT
µA
nA
Table 5-20. Auxiliary Supplies, Auxiliary Supply Monitor
over operating free-air temperature range (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX UNIT
ICC,Monitor
Average supply current
for monitoring circuitry
drawn from VDSYS
LOCKAUX = 0, AUXMRx = 0
AUX0MD = 0, AUX1MD = 0,
AUX2MD = 1,
VDSYS = DVCC, VASYS = AVCC,
Current measured at VDSYS
1.10 µA
IMeas,Montior
Average current drawn
from monitored supply
during measurement
cycle
LOCKAUX = 0, AUXMRx = 0
AUX0MD = 0, AUX1MD = 0,
AUX2MD = 1,
VDSYS = DVCC, VASYS = AVCC,
Current measured at AUXVCC1
0.13 µA
General
VSVMH
VSVMH
VSVMH
(SVSMHRRLx (SVSMHRRLx (SVSMHRRLx
= AUXLVLx) = AUXLVLx) = AUXLVLx)
X - 5%
X + 5%
AUXLVLx = 0
1.65
1.75
1.85
VMonitor
Auxiliary supply
threshold level (same as
high-side SVM)
AUXLVLx = 1
AUXLVLx = 2
AUXLVLx = 3
1.85
1.95
2.05
2.05
2.15
2.25 V
2.15
2.25
2.35
AUXLVLx = 4
2.30
2.40
2.55
AUXLVLx = 5
2.57
2.70
2.83
AUXLVLx = 6
2.90
3.00
3.20
AUXLVLx = 7
2.90
3.00
3.20
Copyright © 2014, Texas Instruments Incorporated
Specifications
41
Submit Documentation Feedback
Product Folder Links: MSP430F6779A MSP430F6778A MSP430F6777A MSP430F6776A MSP430F6775A
MSP430F6769A MSP430F6768A MSP430F6767A MSP430F6766A MSP430F6765A MSP430F6749A
MSP430F6748A MSP430F6747A MSP430F6746A MSP430F6745A