English
Language : 

MSP430F6779A Datasheet, PDF (36/176 Pages) Texas Instruments – Polyphase Metering SoCs
MSP430F6779A, MSP430F6778A, MSP430F6777A, MSP430F6776A, MSP430F6775A
MSP430F6769A, MSP430F6768A, MSP430F6767A, MSP430F6766A, MSP430F6765A
MSP430F6749A, MSP430F6748A, MSP430F6747A, MSP430F6746A, MSP430F6745A
SLAS982 – MAY 2014
www.ti.com
Table 5-9. Outputs – General Purpose I/O (Full Drive Strength)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
VOH High-level output voltage
VOL Low-level output voltage
TEST CONDITIONS
I(OHmax) = –3 mA (1)
I(OHmax) = –10 mA(1)
I(OHmax) = –5 mA(1)
I(OHmax) = –15 mA(1)
I(OLmax) = 3 mA (2)
I(OLmax) = 10 mA (3)
I(OLmax) = 5 mA (2)
I(OLmax) = 15 mA(3)
VCC
1.8 V
3V
1.8 V
3V
MIN
MAX UNIT
1.55
1.80
1.20
1.80
V
2.75
3.00
2.40
3.00
0.00
0.25
0.00
0.60
V
0.00
0.25
0.00
0.60
(1) The maximum total current, I(OHmax), for all outputs combined should not exceed ±20 mA to hold the maximum voltage drop specified.
See Section 5.3 for more details.
(2) The maximum total current, I(OLmax), for all outputs combined should not exceed ±48 mA to hold the maximum voltage drop specified.
(3) The maximum total current, I(OLmax), for all outputs combined should not exceed ±100 mA to hold the maximum voltage drop specified.
Table 5-10. Outputs – General Purpose I/O (Reduced Drive Strength)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)(1)
PARAMETER
VOH High-level output voltage
VOL Low-level output voltage
TEST CONDITIONS
I(OHmax) = –1 mA (2)
I(OHmax) = –3 mA(2)
I(OHmax) = –2 mA(2)
I(OHmax) = –6 mA(2)
I(OLmax) = 1 mA (3)
I(OLmax) = 3 mA (4)
I(OLmax) = 2 mA (3)
I(OLmax) = 6 mA (4)
VCC
1.8 V
3V
1.8 V
3V
MIN
MAX UNIT
1.55
1.80
1.20
1.80
V
2.75
3.00
2.40
3.00
0.00
0.25
0.00
0.60
V
0.00
0.25
0.00
0.60
(1) Selecting reduced drive strength may reduce EMI.
(2) The maximum total current, I(OHmax), for all outputs combined should not exceed ±20 mA to hold the maximum voltage drop specified.
See Section 5.3 for more details.
(3) The maximum total current, I(OLmax), for all outputs combined, should not exceed ±48 mA to hold the maximum voltage drop specified.
(4) The maximum total current, I(OLmax), for all outputs combined, should not exceed ±100 mA to hold the maximum voltage drop specified.
Table 5-11. Output Frequency – General Purpose I/O
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN MAX UNIT
fPx.y
Port output frequency (with load)
See (1) (2)
VCC = 1.8 V,
PMMCOREVx = 0
VCC = 3 V,
PMMCOREVx = 3
16
MHz
25
fPort_CLK Clock output frequency
ACLK
SMCLK
MCLK
CL = 20 pF(2)
VCC = 1.8 V,
PMMCOREVx = 0
VCC = 3 V,
PMMCOREVx = 3
16
MHz
25
(1) A resistive divider with 2 × R1 between VCC and VSS is used as load. The output is connected to the center tap of the divider. For full
drive strength, R1 = 550 Ω. For reduced drive strength, R1 = 1.6 kΩ. CL = 20 pF is connected to the output to VSS.
(2) The output voltage reaches at least 10% and 90% VCC at the specified toggle frequency.
36
Specifications
Copyright © 2014, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: MSP430F6779A MSP430F6778A MSP430F6777A MSP430F6776A MSP430F6775A
MSP430F6769A MSP430F6768A MSP430F6767A MSP430F6766A MSP430F6765A MSP430F6749A
MSP430F6748A MSP430F6747A MSP430F6746A MSP430F6745A