3.5.10 Output Enable/Disable
The OEb pin provides a convenient method of disabling or enabling all of the output drivers at the same time. When the OEb pin is held
high all outputs will be disabled. When held low, the outputs will all be enabled. Outputs in the enabled state can still be individually
disabled through register control.
3.5.11 Output Disable During LOL
By default, a DSPLL that is out of lock will generate either free-running clocks or generate clocks in holdover mode. There is an option
to disable the outputs when a DSPLL is LOL. This option can be useful to force a downstream PLL into holdover.
3.5.12 Output Disable During XAXB_LOS
The internal oscillator circuit (OSC) in combination with the external crystal (XTAL) provides a critical function for the operation of the
DSPLLs. In the event of a crystal failure, the device will assert an XAXB_LOS alarm. By default, all outputs will be disabled during
assertion of the XAXB_LOS alarm. There is an option to leave the outputs enabled during an XAXB_LOS alarm, but the frequency
accuracy and stability will be indeterminate during this fault condition.The internal oscillator circuit (OSC) in combination with the exter-
nal crystal (XTAL) provides a critical function for the operation of the DSPLLs. In the event of a crystal failure, the device will assert an
XAXB_LOS alarm. By default, all outputs will be disabled during assertion of the XAXB_LOS alarm. There is an option to leave the
outputs enabled during an XAXB_LOS alarm, but the frequency accuracy and stability will be indeterminate during this fault condition.
3.5.13 Output Driver State When Disabled
The disabled state of an output driver is configurable as either disable low or disable high.
3.5.14 Synchronous Enable/Disable Feature
The output drivers provide a selectable synchronous enable/disable feature. Output drivers with this feature active will wait until a clock
period has completed before the driver is disabled or enabled. This prevents unwanted runt pulses from occurring when enabling or
disabling an output. When this feature is turned off, the output clock will disable immediately without waiting for the period to complete.