GS4911B Datasheet, PDF (27/119 Pages) Gennum Corporation – HD/SD/Graphics Clock and Timing Generator with GENLOCK
Table 1-3: Output Timing Signals (Continued)
Signal Name
V Sync
V Blanking
F Sync
Description
Default Output Pin
The V Sync timing signal has a leading edge at the start of the vertical sync
pulse. Its length is determined by the selected video standard (see
Table 1-2), or according to custom timing parameters programmed in the
host interface (see Section 3.10 on page 74).
The leading edge of V Sync is nominally simultaneous with the leading
edge of the first broad pulse.
When in Genlock mode, the output V Sync signal will be phase locked to
the reference VSYNC input. This timing may be offset using the Genlock
Offset registers beginning at address 1Bh of the host interface (see
Section 3.2.1.1 on page 38).
By default, after system reset, the polarity of the V Sync signal output will
be active LOW. The polarity may be selected as active HIGH by
programming the Polarity register at address 56h of the host interface
(see Section 3.12.3 on page 79).
TIMING_OUT_3
The V Blanking signal is used to indicate the portion of the video
field/frame not containing active video lines.
The V Blanking signal will be LOW (default polarity) for the portion of the
field/frame containing valid video data, and will be HIGH throughout the
vertical blanking period.
The width of this signal will be determined by the selected video standard
(see Table 1-2), or according to custom timing parameters programmed in
the host interface (see Section 3.10 on page 74).
When in Genlock mode, the output V Blanking signal will be phase locked
to the reference VSYNC input. This timing may be offset using the Genlock
Offset registers beginning at address 1Bh of the host interface (see
Section 3.2.1.1 on page 38).
The default polarity of this signal may be inverted by programming the
Polarity register at address 56h of the host interface (see Section 3.12.3 on
page 79).
NOTE: When VID_STD = 4, 6, or 8, the Vblank output pulse width is 2 lines
too long for field 1 and 1 line too short for field 2 when compared to the
digital timing defined in ITU-R BT.656 and ITU-R BT.799.
TIMING_OUT_4
The F Sync signal is used to indicate field 1 and field 2 for interlaced video
formats.
The F Sync signal will be HIGH (default polarity) for the entire period of
field 1. It will be LOW for all lines in field 2 and for all lines in progressive
scan systems.
The width and timing of this signal will be determined by the V Sync
parameters of the selected video standard (see Table 1-2), or according to
custom V Sync timing parameters programmed in the host interface (see
Section 3.10 on page 74). The F Sync signal always changes state on the
leading edge of V Sync.
When in Genlock mode, the output F Sync signal will be phase locked to
the reference FSYNC input. This timing may be offset using the Genlock
Offset registers beginning at address 1Bh of the host interface (see
Section 3.2.1.1 on page 38).
The default polarity of this signal may be inverted by programming the
Polarity register at address 56h of the host interface (see Section 3.12.3 on
page 79).
TIMING_OUT_5
GS4911B/GS4910B HD/SD/Graphics Clock and Timing
Generator with GENLOCK
Data Sheet
36655 - 5