English
Language : 

HYB18T512400AF Datasheet, PDF (36/58 Pages) Infineon Technologies AG – 512-Mbit DDR2 SDRAM
Internet Data Sheet
HYB18T512[40/80/16]0AF(L)–[3/3S/3.7/5]
512-Mbit DDR2 SDRAM
6
Currents, Specifications,Conditions
This chapter contains the currents, specifications and conditions.
TABLE 35
IDD Measurement Conditions
Parameter
Symbol Note
Operating Current - One bank Active - Precharge
IDD0
tCK = tCK(IDD), tRC = tRC(IDD), tRAS = tRAS.MIN(IDD), CKE is HIGH, CS is HIGH between valid commands. Address
and control inputs are switching; Databus inputs are switching.
Operating Current - One bank Active - Read - Precharge
IDD1
IOUT = 0 mA, BL = 4, tCK = tCK(IDD), tRC = tRC(IDD), tRAS = tRAS.MIN(IDD), tRCD = tRCD(IDD), AL = 0, CL = CL(IDD);
CKE is HIGH, CS is HIGH between valid commands. Address and control inputs are switching; Databus
inputs are switching.
Precharge Power-Down Current
All banks idle; CKE is LOW; tCK = tCK(IDD); Other control and address inputs are stable; Data bus inputs are
floating.
Precharge Standby Current
All banks idle; CS is HIGH; CKE is HIGH; tCK = tCK(IDD); Other control and address inputs are switching,
Data bus inputs are switching.
Precharge Quiet Standby Current
All banks idle; CS is HIGH; CKE is HIGH; tCK = tCK(IDD); Other control and address inputs are stable, Data
bus inputs are floating.
IDD2P
IDD2N
IDD2Q
Active Power-Down Current
IDD3P(0)
All banks open; tCK = tCK(IDD), CKE is LOW; Other control and address inputs are stable; Data bus inputs
are floating. MRS A12 bit is set to “0” (Fast Power-down Exit).
Active Power-Down Current
IDD3P(1)
All banks open; tCK = tCK(IDD), CKE is LOW; Other control and address inputs are stable, Data bus inputs
are floating. MRS A12 bit is set to 1 (Slow Power-down Exit);
Active Standby Current
All banks open; tCK = tCK(IDD); tRAS = tRAS.MAX(IDD), tRP = tRP(IDD); CKE is HIGH, CS is HIGH between valid
commands. Address inputs are switching; Data Bus inputs are switching;
IDD3N
Operating Current
Burst Read: All banks open; Continuous burst reads; BL = 4; AL = 0, CL = CL(IDD); tCK = tCK(IDD); tRAS =
tRAS.MAX.(IDD), tRP = tRP(IDD); CKE is HIGH, CS is HIGH between valid commands. Address inputs are
switching; Data Bus inputs are switching; IOUT = 0 mA.
Operating Current
Burst Write: All banks open; Continuous burst writes; BL = 4; AL = 0, CL = CL(IDD); tCK = tCK(IDD); tRAS =
tRAS.MAX(IDD), tRP = tRP(IDD); CKE is HIGH, CS is HIGH between valid commands. Address inputs are
switching; Data Bus inputs are switching;
IDD4R
IDD4W
Burst Refresh Current
tCK = tCK(IDD), Refresh command every tRFC = tRFC(IDD) interval, CKE is HIGH, CS is HIGH between valid
commands, Other control and address inputs are switching, Data bus inputs are switching.
IDD5B
Distributed Refresh Current
IDD5D
tCK = tCK(IDD), Refresh command every tREFI = 7.8 µs interval, CKE is LOW and CS is HIGH between valid
commands, Other control and address inputs are switching, Data bus inputs are switching.
1)2)3)4)5)
6)
1)2)3)4)5)
6)
1)2)3)4)5)
6)
1)2)3)4)5)
6)
1)2)3)4)5)
6)
1)2)3)4)5)
6)
1)2)3)4)5)
6)
1)2)3)4)5)
6)
1)2)3)4)5)
6)
1)2)3)4)5)
6)
1)2)3)4)5)
6)
1)2)3)4)5)
6)
Rev. 1.71, 2007-01
36
03062006-CPCN-4867