English
Language : 

LTC3883 Datasheet, PDF (91/112 Pages) Linear Technology – Single Phase Step-Down DC/DC Controller with Digital Power System Management
LTC3883/LTC3883-1
PMBus Command Details
Identification
COMMAND NAME
PMBUS_REVISION
CAPABILITY
MFR_DATE
MFR_ID
MFR_LOCATION
MFR_MODEL
MFR_REVISION
MFR_ROM_CRC
MFR_SPECIAL_ID
MFR_TRIM
CMD CODE DESCRIPTION
0x98 PMBus revision supported by this device. Current revision
is 1.1.
0x19 Summary of PMBus optional communication protocols
supported by this device.
0x9D Date of the final test of the IC YYMMDD in ASCII.
0x99 The manufacturer ID of the LTC3883 in ASCII.
0x9C Location of the final test of the LTC3883 in ASCII.
0x9A Manufacturer part number in ASCII.
0x9B Manufacturer part revision in ASCII.
0xFC Factory use only.
0xE7 Manufacturer code representing the LTC3883 and
revision.
0xEB Contact the factory, this command is used for diagnostics.
TYPE
R Byte
R Byte
R String
R String
R String
R String
R String
R Word
R Word
R Block
DATA
FORMAT
Reg
Reg
ASC
ASC
ASC
ASC
ASC
I16
Reg
CF
UNITS
DEFAULT
NVM VALUE
FS
0x11
0xB0
FS
NA
LTC
FS
NA
LTC3883
FS
NA
NA
0x43XX
NA
PMBus_REVISION
The PMBUS_REVISION command indicates the revision of the PMBus to which the device is compliant. The LTC3883
is PMBus Version 1.1 compliant in both Part I and Part II.
This read-only command has one data byte.
CAPABILITY
This command provides a way for a host system to determine some key capabilities of a PMBus device.
The LTC3883 supports packet error checking, 400kHz bus speeds, and ALERT pin.
This read-only command has one data byte.
MFR_DATE
The MFR_DATE command indicates the date of final test of this IC.
The MFR_DATE format is YYMMDD where Y, M and D are integer values from 0 to 9, inclusive using ASCII
characters.
This read-only command is in block format.
MFR_ID
The MFR_ID command indicates the manufacturer ID of the LTC3883 using ASCII characters.
This read-only command is in block format.
MFR_LOCATION
The MFR_LOCATION command indicates the location of final test of this IC using ASCII characters. This field is limited
to a maximum of three characters.
This read-only command is in block format.
3883f
91