GS2961 Datasheet, PDF (81/104 Pages) Gennum Corporation – 3Gb/s, HD, SD SDI Receiver, with Integrated Adaptive Cable Equalizer complete with SMPTE Video Processing
Table 4-17: GSPI Timing Parameters (50% levels; 3.3V or 1.8V operation)
Parameter
CS low before SCLK rising edge
SCLK period
SCLK duty cycle
Input data setup time
Time between end of Command Word (or data in
Auto-Increment mode) and the first SCLK of the
following Data Word – write cycle
Time between end of Command Word (or data in
Auto-Increment mode) and the first SCLK of the
following Data Word – read cycle.
Time between end of Command Word (or data in
Auto-Increment mode) and the first SCLK of the
following Data Word – read cycle - ANC FIFO Read
Output hold time (15pF load)
CS high after last SCLK rising edge
Input data hold time
Symbol
Min
t0
1.5
t1
16.67
t2
40
t3
1.5
t4
PCLK (MHz)
ns
unlocked
100
27.0
37.1
74.25
13.5
148.5
6.7
t5
PCLK (MHz)
ns
unlocked
−
27.0
148.4
74.25
53.9
148.5
27
t5
222.6
t6
1.5
t7
PCLK (MHz)
ns
unlocked
445
27.0
37.1
74.25
13.5
148.5
6.7
t8
1.5
This timing must be satisfied across all ambient temperature and power supply
operating conditions, as described in the Electrical Characteristics on page 15.
Typ
Max Units
−
−
ns
−
−
ns
50
60
%
−
−
ns
−
−
ns
−
−
ns
−
−
ns
−
−
ns
−
−
ns
−
−
ns
GS2961 3Gb/s, HD, SD SDI Receiver, with Integrated
Adaptive Cable Equalizer
Data Sheet
48004 - 2
November 2009
81 of 104