PXD10 Datasheet, PDF (30/130 Pages) Lumins Inc. – 4” Dia.X 6” extruded aluminum step poles | |||
|
◁ |
Pinout and signal descriptions
2.3 Pad configuration during reset phases
All pads have a fixed configuration under reset.
During the power-up phase, all pads are forced to tristate.
After power-up phase, all pads are floating with the following exceptions:
⢠PB[5] (FAB) is pull-down. Without external strong pullup the device starts fetching from flash.
⢠RESET pad is driven low. This is released only after PHASE2 reset completion.
⢠Main oscillator pads (EXTAL, XTAL) are tristate.
⢠Nexus output pads (MDO[n], MCKO, EVTO, MSEO) are forced to output.
⢠The following pads are pullup:
â PB[6]
â PH[0]
â PH[1]
â PH[3]
â EVTI
2.4 Voltage supply pins
Voltage supply pins are used to provide power to the device. Two dedicated pins are used for 1.2 V
regulator stabilization.
There is a preferred power-up sequence for devices in the PXD10 family. That sequence is described in
the following paragraphs.
Broadly, the supply voltages can be grouped as follows:
⢠VREG HV supply (VDDR)
⢠Generic I/O supply
â VDDA
â VDDE_A
â VDDE_B
â VDDE_C
â VDDE_E
â VDDMA
â VDDMB
â VDDMC
â VDDPLL
⢠LV supply (VDD12)
The preferred order of ramp up is as follows:
1. Generic I/O supply
PXD10 Microcontroller Data Sheet, Rev. 1
30
Freescale Semiconductor
|
▷ |