English
Language : 

UG534 Datasheet, PDF (80/96 Pages) –
Appendix B: Default Switch and Jumper Settings
Table B-35: Default Jumper Settings
Jumper REFDES
Function
J69
System ACE CF Error LED Enable
GMII:
J66
pins 1-2: GMII/MII to Cu
pins 2-3: SGMII to Cu, no clk
J67
pins 1-2: GMII/MII to Cu
pins 2-3: SGMII to Cu, no clk
J68
J66 pins 1-2, J68 ON: RGMII, modified MII in Cu
FMC JTAG Bypass:
J18
exclude FMC LPC connector
J17
exclude FMC HPC connector
System Monitor:
J19
Test_mon_vrefp sourced by U23, REF3012
J35
measure voltage across R-kelvin on VCCINT
SFP Module:
J54
J65
PCIe Lane Size:
J42
Full BW
SFP Enable
1 lane
Default
Jump 1-2
Jump 1 - 2
Jump 1 - 2
no jumper
Jump 1 - 2
Jump 1 - 2
Jump 1 - 2
Jump 9 - 11,
Jump 10 - 12
Jump 1 - 2
Jump 1 - 2
Jump 1 - 2
80
www.xilinx.com
ML605 Hardware User Guide
UG534 (v1.8) October 2, 2012