English
Language : 

UG534 Datasheet, PDF (21/96 Pages) –
Detailed Description
Table 1-4: DDR3 SODIMM Connections (Cont’d)
U1 FPGA Pin
Schematic Net Name
C30
DDR3_DQS7_P
J1 SODIMM
Pin Number
Pin Name
188
DQS7_P
F18
DDR3_ODT0
E17
DDR3_ODT1
E18
DDR3_RESET_B
K18
DDR3_S0_B
K17
DDR3_S1_B
D17
DDR3_TEMP_EVENT
B17
DDR3_WE_B
C17
DDR3_CAS_B
L19
DDR3_RAS_B
M18
DDR3_CKE0
M17
DDR3_CKE1
H18
DDR3_CLK0_N
G18
DDR3_CLK0_P
L16
DDR3_CLK1_N
K16
DDR3_CLK1_P
116
ODT0
120
ODT1
30
RESET_B
114
S0_B
121
S1_B
198
EVENT_B
113
WE_B
115
CAS_B
110
RAS_B
73
CKE0
74
CKE1
103
CK0_N
101
CK0_P
104
CK1_N
102
CK1_P
The Memory Interface Generator (MIG) tool guidelines specify a set of U1 FPGA “No
Connect” pins. These should be added to the UCF as CONFIG PROHIBIT pins as follows:
CONFIG PROHIBIT = H22;
CONFIG PROHIBIT = F21;
CONFIG PROHIBIT = B20;
CONFIG PROHIBIT = F19;
CONFIG PROHIBIT = C13;
CONFIG PROHIBIT = M12;
CONFIG PROHIBIT = L13;
CONFIG PROHIBIT = K14;
CONFIG PROHIBIT = F25;
CONFIG PROHIBIT = C29;
CONFIG PROHIBIT = C28;
CONFIG PROHIBIT = D24;
References
See the Micron Technology, Inc. for more information [Ref 22].
In addition, see the Virtex-6 FPGA Memory Interface Solutions User Guide [Ref 6] and the
Virtex-6 FPGA Memory Resources User Guide [Ref 9].
ML605 Hardware User Guide
www.xilinx.com
21
UG534 (v1.8) October 2, 2012