9. ELECTRICAL CHARACTERISTIC
9.1 Absolute Maximum DC, AC Ratings
Parameter
Min
Max
Unit
Operating temperature (case) Wireless
-40
+85
ºC
Storage temperature (plastic)
-55
+150
ºC
Soldering temperature and time 10s (solder ball only)
+260
ºC
Voltage to any ball except VCC, VCCQ relative to VSS
-0.3
VCCQ +0.3
V
Voltage on VCC supply relative to VSS
-0.20
+2.45
V
Voltage on VCCQ supply relative to VSS
-0.20
+2.45
V
Stresses greater than those listed may cause permanent damage to the device. This is a stress rating only, and
functional operation of the device at these or any other conditions above those indicated in the operational sections of
this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect
reliability.
9.2 Electrical Characteristics and Operating Conditions
Description
Conditions
Symbol
Min
Max Unit Note
Supply voltage
VCC
1.7
1.95
V
I/O supply voltage
VCCQ
1.7
1.95
V
Input high voltage
VIH
VCCQ–0.4 VCCQ+0.2 V
1
Input low voltage
VIL
–0.20
0.4
V
2
Output high voltage
IOH=–0.2mA
VOH
0.8xVCCQ
V
3
Output low voltage
IOL=+0.2mA
VOL
0.2xVCCQ V
3
Input leakage current
VIN=0 toVCCQ
ILI
1
μA
Output leakage current OE#=VIH or chip disabled
ILO
1
μA
OPERATING CURRENT
Asynchronous random
READ/WRITE
ICC1 tRC/tWC=70ns
-
25
mA
4
Initial access,
133MHz
-
ICC2
burst READ/WRITE
VIN = VCCQ or 0V chip enabled,
104MHz
-
40
mA
4
35
IOUT=0
Continuous burst READ
133MHz
-
ICC3R
104MHz
-
35
mA
4
30
Continuous burst WRITE
133MHz
-
ICC3W
104MHz
-
40
mA
4
35
Standby Current
VIN = VCCQ or 0V, CE# = VCCQ
ISB
Standard
-
400
uA 5,6
Notes: 1. Input signals may overshoot to VCCQ + 1.0V for periods less than 2ns during transitions.
2. Input signals may undershoot to VSS – 1.0V for periods less than 2ns during transitions.
3. BCR[5:4] = 01b (default setting of one-half drive strength).
4.This parameter is specified with the outputs disabled to avoid external loading effects. The user must add the current
required to drive output capacitance expected in the actual system.
5.ISB (max) values measured with PAR set to FULL ARRAY and at +85°C. In order to achieve low standby current, all inputs
must be driven to either VCCQ or VSS. ISB might be slightly higher for up to 500ms after power-up, or when entering
standby mode.