English
Language : 

TA1360AFG_05 Datasheet, PDF (87/110 Pages) Toshiba Semiconductor – YCbCr/YPbPr Signal and Sync Processor for Digital TV, Progressive Scan TV and Double Scan TV
TA1360AFG
Note
No.
Characteristics
SW68
T19 IK input
A
amplitude
or
C
SW67
B
SW66
B
Test Conditions
SW Mode
SW26 SW25 SW24
A
A
A
SW21
A
SW19
A
SW18
A 1.
2.
3.
Test Method
Input signal 1(f0 = 100 kHz, picture period amplitude = 0.2 Vp-p) from pin 68. Control drive
gain adjustment data so that pins 14 and 13 picture period amplitude equals that of pin 12.
Set subaddress (02) data to (40).
Measure voltage amplitude of pin-8 input signal in ACB insertion period.
1H = IKR 2H = IKG 3H = IKB
T20 IK input cover C
B
B
A
A
A
A
A
A 1. Input signal 1(f0 = 100 kHz, picture period amplitude = 0.2 Vp-p) from pin 68. Control drive
range
gain adjustment data so that pins 14 and 13 picture period amplitude equals that of pin 12.
2. Set subaddress (02) data to (40).
3. Measure pin 8 DC voltage in Vï½¥BLK period. (#8VBLK)
4. Apply the current externally to pin 8.
5. Measure DC voltage of pin 8 in Vï½¥BLK period when pin-12 picture period voltage begins to
be decreased. (#8VBLK+)
6. Apply current outward from pin 8.
7. Measure DC voltage of pin 8 in Vï½¥BLK period when pin-12 picture period voltage begins to
be increased. (#8VBLK−)
8. DIKin+ = (#8VBLK+) − (#8VBLK)
DIKin− = (#8VBLK−) + (#8VBLK)
T21 Analog RGB
A
B
B
A
A
A
A
A
A 1. Input signal 1(f0 = 100 kHz, picture period amplitude = 0.2 Vp-p) from pin 68. Control drive
gain
or
or
or
gain adjustment data so that pins 14 and 13 picture period amplitude equals that of pin 12.
B
B
B
2. Apply 5-V external voltage to pin 2.
3. Input signal 1(f0 = 100 kHz, picture period amplitude = 0.2 Vp-p) from pin 24.
4. Measure pin 12 picture period amplitude, v12R.
5. Repeat the steps 3 and 4 above with the following pins:
Input from pin 25, and measure output from pin 13 (v13G).
Input from pin 26, and measure output from pin 14 (v14B).
6 Calculate the following equations. GTXR = v12R/0.2 GTXG = v13G/0.2 GTXB = v14B/0.2
T22 Analog RGB
A
B
B
A
A
A
A
A
A 1. Input signal 1(f0 = 100 kHz, picture period amplitude = 0.2 Vp-p) from pin 68. Control drive
white peak
gain adjustment data so that pins 14 and 13 picture period amplitude equals that of pin 12.
slice level
2. Apply 5-V external voltage to pin 2.
3. Set RGB contrast data to maximum (7F).
4. Input signal 2 to pin 24. Gradually increase picture amplitude, and measure picture period
amplitude voltage when output from pin 12 is clipped.
5. Repeat the steps 3 and 4 above with following pins: Input from pin 25 and measure output
from pin 13. Input from pin 26 and measure output pin 14.
87
2005-08-18