P29 Y detail control range
TA1360AFG
SW71
B
Test Conditions
SW Mode
SW70 SW68 SW64
B
A
B
SW74
Test Method (Test condition: VCC = 9 V/2 V, Ta = 25 ± 3°C)
ON 1. Set unicolor to maximum (1111111), SRT-GAIN to minimum (00000), CDE to center (10), and APACON
peak frequency to 4.5 M (11). Input SWEEP signal to TPA.
2. Set #68 amplitude to 20mVp-p.
3. Set picture sharpness to center (1000000), Y detail control to maximum (1111), and monitor #12 with a
spectrum analyzer.
4. Set low frequency area to 0dB, and measure each peak level GYDMAX.
5. Set Y detail control to center (1000), and measure peak level GYDCEN.
6. Set Y detail control to minimum (0000), and measure peak level GYDMIN.
69