English
Language : 

TA1360AFG_05 Datasheet, PDF (100/110 Pages) Toshiba Semiconductor – YCbCr/YPbPr Signal and Sync Processor for Digital TV, Progressive Scan TV and Double Scan TV
TA1360AFG
Note Characteristics
Test Conditions
HA09 Black peak detection 1. Set subaddress (00) data to 40H.
pulse phase and
level
2. Set SW70 to C, SW68 to C, and SW39A to OPEN
3. Input signal C (as the figure shown below) to #39 (FBP input).
4. Measure #70 (BPH filter) black peak detection pulse phase (HBPS00a and HBPS00b) in relation
to signal C.
5. Set HBP-PHS 1/2 to (01), (10), and (11). Measure black peak detection pulse phase.
Signal C
HBPS**a
31.5 µs
4.13 µs
2V
0V
HBPS**b
#70 waveform
HA10 FBP input threshold
1. Set subaddress (00) data to 40H.
2. Input signal B (as shown in the figure below) to TP50.
3. Increase amplitude of FBP signal to be input to #39 (FBP input) from 0 Vp-p. When #37
(H-OUT) phase locks with that of signal B, measure #39 input amplitude VthFBP.
31.75 µs
2.35 µs
1.5 V
100
2005-08-18