Test Condition for Picture Quality (Sharpness) Block
Common Test Condition for Picture Quality (Sharpness) Block
1. SW67 = SW66 = B, SW63 = B, SW60 to SW61 = B, SW44 = ON, SW40 = B, SW18 to SW26 = A, SW77 = OPEN
2. Send bus control data as preset values, turn ACB operation switching to ACB OFF (00), select Sync input (1), turn P-MODE to Normal 1(000), WPL-LEVEL to
max (111), and change subaddress (1C) to (03).
3. Input sync signal, which is in sync with input signal for testing except âSweepâ, to #53 (Sync input). âH-Freq.â should be the same frequency as the one of #53.
4. Set Y/color difference input mode to (0), sync separator level to 20 % (01), and vertical free-running frequency to 307H (110).
Note No.
Characteristics
P01 Black detection level shift
SW71
B
Test Conditions
SW Mode
SW70 SW68 SW64
C
C
B
SW74
Test Method (Test condition: VCC = 9 V/2 V, Ta = 25 ± 3°C)
OPEN 1. Connect external power supply PS to #68, and monitor #70 and #74.
2. Set black stretch point 1 to OFF (000), and black detection level to 0 IRE (1).
3. Increase PS voltage from 4.95 V in steps of 1 mV. At the moment when #70 picture period (High) drops to
Low level, monitor DC difference on #74 VB.
4. Set black detection level to 3 IRE (0).
5. Repeat the step 3 above and monitor DC difference, VB3 on #74.
#74 waveform
VB, VB3
#70 waveform
P02 Black stretch amp maximum
B
A
A
B OPEN 1. Set SW70 to A (maximum gain), and input 500-kHz sine wave to TPA.
gain
2. Adjust signal amplitude to 0.1 Vp-p on #68.
3. Set black stretch point 1 to OFF (000), and measure #74 amplitude VA.
4. Set black stretch point 1 to 001 (black stretch ON), and measure #74 amplitude VB.
5. Calculate GBS using a following equation.
GBS = 20 à log (VB ÷ VA) [dB]
44
2005-08-18
|
▷ |