TA1360AFG_05 Datasheet, PDF (63/110 Pages) Toshiba Semiconductor – YCbCr/YPbPr Signal and Sync Processor for Digital TV, Progressive Scan TV and Double Scan TV
Note No.
Characteristics
P22 Sharpness control center
characteristic
TA1360AFG
SW71
B
Test Conditions
SW Mode
SW70 SW68 SW64
B
A
B
SW74
ON 1.
2.
3.
4.
5.
6.
7.
8.
9.
Test Method (Test condition: VCC = 9 V/2 V, Ta = 25 ± 3°C)
Input sine wave to TPA. (The frequency is variable.)
Set the amplitude of #68 to 20 mVp-p.
Set unicolor to maximum (1111111), SRT-GAIN to minimum (00000), APACON peak frequency to 13.5 M
(00), and color detail enhancer (CDE) to center (10).
Set picture mute to OFF (P-MODE: Normal 1, 000), and monitor #12.
Set picture sharpness to center (1000000). Set input frequency to 100 kHz, and measure the amplitude
V100.
Set picture sharpness to center (1000000). Set input frequency to FAP00, measure #12 amplitude VCEN00,
and calculate GCEN00 using the following equations.
Set APACON peak frequency to 9.5 M (01). Set input frequency to FAP01, measure VCEN01 and calculate
GCEN01.
Set APACON peak frequency to 6.4 M (10). Set input frequency to FAP10, measure VCEN10 and calculate
GCEN10.
Set APACON peak frequency to 4.5 M (11). Set input frequency to FAP11, measure VCEN11 and calculate
GCEN11.
GCEN*** = 20 × log (VCEN*** ÷ V100) [dB]
Note: When a spectrum analyzer is used, measure gain for low frequency.
63
2005-08-18