5.3.2. Tracking Modes
Each ADC0 conversion must be preceded by a minimum tracking time in order for the converted result to
be accurate. The minimum tracking time is given in Table 5.1. The AD0TM bit in register ADC0CN controls
the ADC0 track-and-hold mode. In its default state, the ADC0 input is continuously tracked, except when a
conversion is in progress. When the AD0TM bit is logic 1, ADC0 operates in low-power track-and-hold
mode. In this mode, each conversion is preceded by a tracking period of 3 SAR clocks (after the start-of-
conversion signal). When the CNVSTR signal is used to initiate conversions in low-power tracking mode,
ADC0 tracks only when CNVSTR is low; conversion begins on the rising edge of CNVSTR (see
Figure 5.3). Tracking can also be disabled (shutdown) when the device is in low power standby or sleep
modes. Low-power track-and-hold mode is also useful when AMUX settings are frequently changed, due
to the settling time requirements described in Section “5.3.3. Settling Time Requirements” on page 48.
CNVSTR
(AD0CM[2:0]=100)
SAR Clocks
A. ADC0 Timing for External Trigger Source
1 2 3 4 5 6 7 8 9 10 11
AD0TM=1
Low Power
or Convert
Track
Convert
Low Power
Mode
AD0TM=0
Track or Convert
Convert
Track
Write '1' to AD0BUSY,
Timer 0, Timer 2,
Timer 1, Timer 3 Overflow
(AD0CM[2:0]=000, 001,010
011, 101)
SAR Clocks
AD0TM=1
B. ADC0 Timing for Internal Trigger Source
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Low Power
or Convert
Track
Convert
Low Power Mode
SAR Clocks
AD0TM=0
1 2 3 4 5 6 7 8 9 10 11
Track or
Convert
Convert
Track
Figure 5.3. 10-Bit ADC Track and Conversion Example Timing