SDA 9361
3.1 Recommended Operating Conditions (cont’d)
Parameter
Symbol
Limit Values
min. nom. max.
Input Φ2
L-input voltage
VIL
0
0.7
H-input voltage
VIH
2.0
VDD
Input HSYNC (CLEXT = 0)
Input voltage range VHSpp 2
VDD
Input voltage low level VHSmin 0
Input voltage high level VHSmax
VDD
Pulse width
tw
3.0
6.1
(HSWID = 0)
1.5
3.1
Pulse width
tw
3.0
8.8
(HSWID = 1)
1.5
4.0
Rise time
tr
100
Input HSYNC (CLEXT = 1)
L-input voltage
VIL
0
0.8
H-input voltage
VIH
2.0
VDD
Setup time
tSU
4
Unit
V
V
V
V
µs
µs
µs
µs
ns
V
V
ns
Hold time
tH
12
ns
Input VSYNC
Pulse width high
Pulse width high
Pulse width high
100
200
1.5/fH
100/fH ns
100/fH ns
100/fH
Remark
VREFP = 4 V
VREFP = 4 V
See page 12
See page 12
See page 12
Low FH-range
High FH-range
Low FH-range
High FH-range
Referred to falling
edge of CLKI
Referred to falling
edge of CLKI
FH1_2 = 1, NI = 0
FH1_2 = 0, NI = 0
NI = 1
Semiconductor Group