SDA 9361
3.1 Recommended Operating Conditions
Parameter
Symbol
Limit Values Unit Remark
min. nom. max.
Supply voltages
VDD
Ambient temperature TA
4.5 5
-20 25
5.5 V
70 °C
For analog
parameters: 0°C
TTL Inputs: CLKI, VSYNC, TEST, FH1_2, SELFH1_2, CLEXT, SSD, VOFFD, RESN
H-input voltage
L-input voltage
Input VPROT
VIH
2.0
VIL
0
VDD V
0.8 V
Threshold V1
Threshold V2
Input HPROT
1.4 1.5 1.6 V
0.9 1.0 1.1 V
VREFP = 4 V
VREFP = 4 V
Threshold V1
Threshold V2
Input ABL
3.9 4
4.1 V
2.1 2.4 2.7 V
VREFP = 4 V
VREFP = 4 V
L-input voltage
VIL
2
V
VREFP = 4 V
RABL = 0
Full range input
voltage
0
V
VREFP = 4 V RABL = 1
3
V
VREFP = 4 V
RABL = 0
4
V
VREFP = 4 V RABL = 1
Reference Voltage Input Pins (Internal Voltage Ref. Control Byte Reg 48H = 00000110)
VREFP input voltage VVREFP
4
VREFH input voltage VVREFH
2.5
VREFL input voltage VVREFL
1.2
VREFN input voltage VVREFN
0
VREFC input voltage VVREFC
5
V
V
V
V
V
Independent of
register 48H,
max = VDD
Semiconductor Group